Feasibility of transradial coronary intervention using a sheathless guiding catheter in patients with small radial artery.
Korean Circulation Journal 2011 March
BACKGROUND AND OBJECTIVES: Transradial coronary angiography and intervention are increasing in frequency due to lower major vascular access site complications and the potential for early mobilization. However, the small size of the radial artery (RA) is a major limitation of this technique. A sheathless guiding catheter (GC) has recently been introduced that has a 1-2 French smaller diameter compared with the corresponding introducer sheath. This catheter also has a hydrophilic coating along its entire length. We evaluated the feasibility of using a sheathless GC in patients who have small radial arteries.
SUBJECTS AND METHODS: The procedural results were evaluated in patients with small radial arteries (diameter <2.3 mm) who underwent transradial coronary intervention using a sheathless GC.
RESULTS: A total of 25 (male: 9) patients with 29 lesions were enrolled. The mean RA diameter was 1.81±0.26 mm. 44% of the patients had stable angina and 50.0% had acute coronary syndrome. The procedural success rate was 93.1%. Two patients (6.9%) had chronic total occlusive lesions that could not be crossed with a guide-wire despite good guiding support. An intravascular ultrasound could be used for all of the treated lesions. Multi-vessel intervention was performed in 29.2% of the patients. Two bifurcated lesions were treated with a kissing balloon technique, and one with a modified T-stenting technique. No catheter related complications were reported.
CONCLUSION: The use of a sheathless GC is feasible in patients with small radial arteries without catheter related complications.
SUBJECTS AND METHODS: The procedural results were evaluated in patients with small radial arteries (diameter <2.3 mm) who underwent transradial coronary intervention using a sheathless GC.
RESULTS: A total of 25 (male: 9) patients with 29 lesions were enrolled. The mean RA diameter was 1.81±0.26 mm. 44% of the patients had stable angina and 50.0% had acute coronary syndrome. The procedural success rate was 93.1%. Two patients (6.9%) had chronic total occlusive lesions that could not be crossed with a guide-wire despite good guiding support. An intravascular ultrasound could be used for all of the treated lesions. Multi-vessel intervention was performed in 29.2% of the patients. Two bifurcated lesions were treated with a kissing balloon technique, and one with a modified T-stenting technique. No catheter related complications were reported.
CONCLUSION: The use of a sheathless GC is feasible in patients with small radial arteries without catheter related complications.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app