Use of the Cogan lid twitch to identify myasthenia gravis.
Journal of Neuro-ophthalmology : the Official Journal of the North American Neuro-Ophthalmology Society 2011 September
BACKGROUND: To evaluate the reliability of the Cogan lid twitch (CLT) test in a neuro-ophthalmology clinic.
METHODS: CLT testing was performed on adult patients presenting to the neuro-ophthalmology clinic by the neuro-ophthalmologist. The patients were instructed to look straight ahead, up, down, and straight ahead again. The upper eyelids were carefully evaluated immediately following this movement for the presence of a brief upward twitch of the upper eyelid, which would indicate a positive CLT test. The test was repeated as needed. We evaluated the findings from the ophthalmologic examination along with results of available tests, such as serologic findings, MRIs, and CTs.
RESULTS: Of 117 patients evaluated, 24 had myasthenia gravis (MG), and 18 of these patients had a positive lid twitch. Of the 98 patients who did not display a positive Cogan twitch, 6 had MG. We calculated the specificity of the CLT to be 99%, with a sensitivity 75% and false-positive rate 1%.
CONCLUSION: The CLT test is a specific and sensitive test to use in a neuro-ophthalmology clinic to evaluate for MG.
METHODS: CLT testing was performed on adult patients presenting to the neuro-ophthalmology clinic by the neuro-ophthalmologist. The patients were instructed to look straight ahead, up, down, and straight ahead again. The upper eyelids were carefully evaluated immediately following this movement for the presence of a brief upward twitch of the upper eyelid, which would indicate a positive CLT test. The test was repeated as needed. We evaluated the findings from the ophthalmologic examination along with results of available tests, such as serologic findings, MRIs, and CTs.
RESULTS: Of 117 patients evaluated, 24 had myasthenia gravis (MG), and 18 of these patients had a positive lid twitch. Of the 98 patients who did not display a positive Cogan twitch, 6 had MG. We calculated the specificity of the CLT to be 99%, with a sensitivity 75% and false-positive rate 1%.
CONCLUSION: The CLT test is a specific and sensitive test to use in a neuro-ophthalmology clinic to evaluate for MG.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app