Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.

PURPOSE: To compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma.

METHODS: One hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interactive thresholding algorithm (SITA) SWAP at the same visit (all perimeters by Carl Zeiss Meditec, Inc., Dublin, CA). Visual field defects were confirmed with two or more consecutive examinations by the same types of perimetry. Glaucoma was defined with the reference to the RNFL thickness deviation map score (≥ 4, glaucomatous; ≤ 2, normal). The sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of MD (mean deviation) and PSD (pattern standard deviation) of the perimetries were compared.

RESULTS: Taking all glaucoma patients into consideration, the sensitivity was highest for Matrix FDT perimetry (69%), followed by SAP (68%), and then SITA SWAP (59%). When the analysis included only patients with early glaucoma, the sensitivity decreased to 52%, 46%, and 34%, respectively, with a significant difference detected between Matrix FDT perimetry and SITA SWAP (P = 0.034). The specificity was ≥ 97% for all perimetries. The AUCs of MD and PSD followed a similar order, with Matrix FDT perimetry having the greatest AUC (0.89-0.94), followed by SAP (0.87-0.94), and then SITA SWAP (0.69-0.90). There were significant differences in sensitivities at 90% specificity between Matrix FDT perimetry and SITA SWAP (P ≤ 0.005 for MD; P ≤ 0.039 for PSD).

CONCLUSIONS: The performance for glaucoma detection was comparable between FDT perimetry and SAP. FDT perimetry had a higher sensitivity for detecting glaucoma than did SWAP at a comparable level of specificity.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app