We have located links that may give you full text access.
Comparative Study
Journal Article
Multicenter Study
Randomized Controlled Trial
Research Support, Non-U.S. Gov't
Safety and effectiveness of a new fibrin pleural air leak sealant: a multicenter, controlled, prospective, parallel-group, randomized clinical trial.
Annals of Thoracic Surgery 2011 October
BACKGROUND: This study evaluated the sealing capacity and safety of a new fibrin sealant (FS) to reduce alveolar air leaks (AALs) after pulmonary resections in a randomized controlled clinical trial conducted in 3 Italian centers.
METHODS: The study randomized (1:1) 185 patients with an intraoperative AAL graded 1 to 3 according to the Macchiarini scale: 91 received FS and 94 had standard lung closure. The primary outcomes were the length of postoperative AAL duration and the mean time to chest drain removal. Other end points included the percentage of patients without AAL, the development of serum antibodies against bovine aprotinin, and any adverse event related to FS. Chest drains were removed when fluid output was 100 mL/day or less, with no air leak.
RESULTS: The study groups were comparable with respect to demographic variables and surgical procedures. The FS group showed a statistically significant reduction in duration of postoperative AALs (9.52 vs 35.8 hours; p < 0.005) and in the percentage of patients with AALs at wound closure (81.11% vs 100%; p < 0.001); the difference in time to chest drain removal was not significant. Pleural empyema developed in 1 patient with FS treatment vs in 4 with standard treatment, and antibodies against bovine aprotinin were found in 34 of 91 FS-treated patients.
CONCLUSIONS: The present study showed that the new FS is safe and effective in preventing AALs after lung resections and in shortening the duration of postoperative AALs.
METHODS: The study randomized (1:1) 185 patients with an intraoperative AAL graded 1 to 3 according to the Macchiarini scale: 91 received FS and 94 had standard lung closure. The primary outcomes were the length of postoperative AAL duration and the mean time to chest drain removal. Other end points included the percentage of patients without AAL, the development of serum antibodies against bovine aprotinin, and any adverse event related to FS. Chest drains were removed when fluid output was 100 mL/day or less, with no air leak.
RESULTS: The study groups were comparable with respect to demographic variables and surgical procedures. The FS group showed a statistically significant reduction in duration of postoperative AALs (9.52 vs 35.8 hours; p < 0.005) and in the percentage of patients with AALs at wound closure (81.11% vs 100%; p < 0.001); the difference in time to chest drain removal was not significant. Pleural empyema developed in 1 patient with FS treatment vs in 4 with standard treatment, and antibodies against bovine aprotinin were found in 34 of 91 FS-treated patients.
CONCLUSIONS: The present study showed that the new FS is safe and effective in preventing AALs after lung resections and in shortening the duration of postoperative AALs.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app