COMPARATIVE STUDY
JOURNAL ARTICLE
Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography.
Journal of Nuclear Cardiology 2012 Februrary
BACKGROUND: Cadmium Zinc Telluride (CZT) SPECT camera technology has the potential to reduce patient's radiation exposure and shorten imaging time. This study evaluated the correlation of low stress tracer dose, rapid CZT SPECT myocardial perfusion imaging (MPI) to coronary angiography in a <200-lbs population to further validate its ability to achieve both goals while preserving diagnostic accuracy.
METHODS: All patients who had a low-dose stress (≤15 mCi) Tc-99m sestamibi SPECT MPI study using a CZT camera (GE Discovery NM 530c) with 3- to 5-minute image acquisition over a 2-year period followed by a coronary angiogram within 2 months were included. Patients with a history of coronary revascularization, left ventricular dysfunction, and LBBB or paced rhythms were excluded. Both MPI studies and coronary angiograms were interpreted by blinded readers and coronary artery disease (CAD) was defined as ≥70% stenosis.
RESULTS: A total of 71 patients were included with a mean age of 64 years, 55% male, and a BMI of 25.4 kg/m(2) with an average stress dose of 13.3 mCi. Exercise stress was performed in 54% of patients and vasodilator pharmacologic stress in 46%. Sensitivity was 89%, specificity was 66%, and accuracy was 78% for detecting obstructive CAD.
CONCLUSIONS: In this group of non-obese patients undergoing low stress dose imaging, high-efficiency CZT SPECT imaging demonstrated a high sensitivity, specificity, and accuracy for detecting obstructive epicardial CAD with a greatly reduced imaging time.
METHODS: All patients who had a low-dose stress (≤15 mCi) Tc-99m sestamibi SPECT MPI study using a CZT camera (GE Discovery NM 530c) with 3- to 5-minute image acquisition over a 2-year period followed by a coronary angiogram within 2 months were included. Patients with a history of coronary revascularization, left ventricular dysfunction, and LBBB or paced rhythms were excluded. Both MPI studies and coronary angiograms were interpreted by blinded readers and coronary artery disease (CAD) was defined as ≥70% stenosis.
RESULTS: A total of 71 patients were included with a mean age of 64 years, 55% male, and a BMI of 25.4 kg/m(2) with an average stress dose of 13.3 mCi. Exercise stress was performed in 54% of patients and vasodilator pharmacologic stress in 46%. Sensitivity was 89%, specificity was 66%, and accuracy was 78% for detecting obstructive CAD.
CONCLUSIONS: In this group of non-obese patients undergoing low stress dose imaging, high-efficiency CZT SPECT imaging demonstrated a high sensitivity, specificity, and accuracy for detecting obstructive epicardial CAD with a greatly reduced imaging time.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app