Mid-term results of third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty: a ten-year minimum follow-up.

BACKGROUND: Alumina ceramic-on-ceramic bearings have gained popularity in hip arthroplasty because of their properties of low wear and chemical inertness. In a previous study, we reported the excellent clinical results in a series of cementless ceramic-on-ceramic primary total hip arthroplasties at a minimum of five years of follow-up. The purpose of the present study was to determine the results in the same patient cohort at a minimum of ten years of follow-up.

METHODS: A series of 301 consecutive primary cementless total hip arthroplasties was assessed clinically and radiographically. Clinical information was available for 244 hips in 227 surviving patients at a minimum of ten years of follow-up, and radiographic information was available for 184 hips in 172 patients.

RESULTS: Twenty-six (9.2%) of the patients had died of an unrelated cause and eight (2.7%) had undergone revision arthroplasty by the time of the latest follow-up. The average Harris hip score was 94 points, with 95% (232) of the patients having an excellent or good result and <4% (nine) having moderate residual pain. All radiographic assessments showed evidence of stable osseous ingrowth. Nine revisions had been performed, including four femoral component revisions due to periprosthetic fracture, one femoral revision due to aseptic loosening, one femoral revision secondary to a femoral shortening osteotomy for nerve palsy, two acetabular cup revisions due to psoas tendinitis, and a repeat revision in one of the patients with psoas tendinitis due to acetabular osteolysis. The overall survival rate of the implants was 98% (95% confidence interval, 94.2% to 99.6%) at ten years with revision for any reason as the end point.

CONCLUSIONS: The patients in our series had a good implant survival rate, good function, a low implant wear rate as reported in the previous study, and no further radiographic evidence of failure at ten years after cementless primary total hip arthroplasty with alumina ceramic-on-ceramic bearings.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app