Optimizing the effectiveness of a mechanical suture-based anulus fibrosus repair construct in an acute failure laboratory simulation.

STUDY DESIGN: In vitro comparative, laboratory experiments.

OBJECTIVE: This study developed a laboratory apparatus that measured resistance to failure using pressures similar to intradiscal pressure of a lumbar spinal disk. Various combinations of an anular repair device were compared.

SUMMARY OF BACKGROUND CONTEXT: Herniated material of the intervertebral disk is removed during a lumbar discectomy; however, the defect in the anulus fibrosus remains and can provide a pathway for future herniation. Repairing the anulus fibrosus could mitigate this reherniation and improve patient outcomes.

METHODS: A pneumatic cylinder was used to increase the pressure of a sealed chamber until artificial nucleus pulposus material was expulsed through either a 3-mm circular (diameter) or a 6-mm slit anular defect created in a surrogate anulus fibrosus. Each unrepaired condition was compared with 3 repaired conditions using a commercially available soft tissue repair system. The repaired conditions included: (1) a single tension band; (2) 2 tension bands in a cruciate pattern; or (3) 2 tension bands in a parallel pattern. Maximum pressure at the point of extrusion of the internal chamber material and failure or nonfailure of the repair was measured.

RESULTS: Significant differences were detected (P<0.05) in maximum failure pressures for the nonrepaired (control) versus repaired conditions. With 1 or 2 tension bands repairing the circular defect, the maximum failure pressure increased by approximately 76% and 131%, respectively. In addition, the failure pressure for 2 tension bands in either a cruciate or parallel configuration was not different, and was approximately 32% higher (P<0.05) than a single tension band in the case of the circular defect. Similar results were seen for the slit defect, with the exception that no difference between the repaired conditions (ie, single vs. 2 tension bands) was detected.

CONCLUSIONS: This laboratory simulation demonstrated that repairing the anulus fibrosus after a discectomy procedure can be beneficial for retaining intradiscal material. The use of 2 tension bands, versus a single tension band, in either a cruciate or parallel configuration may further improve the ability to retain disk material.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app