We have located links that may give you full text access.
Minimally invasive helical plating for shaft of humerus fractures: technique and outcome.
INTRODUCTION: The humerus is subjected to substantial amount of torsional stress. Conventional plating may not address this sufficiently and may lead to fixation failure or non-union. A helical plate may offer the solution. We present the surgical technique and functional outcome of 5 cases of humeral shaft fractures treated with this technique in a minimally invasive way.
MATERIALS AND METHODS: The operations were performed between 2004 and 2010, by three surgeons. All the patients had closed humeral shaft fractures, either simple transverse or with mild comminution. Two small incisions were made. The proximal incision was placed along the deltopectoral groove over the shaft, and the distal incision was placed as in an antero-lateral approach. The radial nerve was identified and protected. A pre-selected plate was contoured and introduced in the submuscular plane. The plate was placed in a proximal-lateral and distal-anterior position. Screws were inserted through stab incisions. The patients were followed for an average of 6 months. Functional recovery of the shoulder and elbow was assessed using the Constant and Mayo elbow performance score systems.
RESULTS: All incisions healed by first intention without complications and all the fractures went on to unite. All patients achieved good to excellent shoulder and elbow function.
CONCLUSION: The helical plate technique is a safe and effective method of treating humeral shaft fractures and has good functional outcome.
MATERIALS AND METHODS: The operations were performed between 2004 and 2010, by three surgeons. All the patients had closed humeral shaft fractures, either simple transverse or with mild comminution. Two small incisions were made. The proximal incision was placed along the deltopectoral groove over the shaft, and the distal incision was placed as in an antero-lateral approach. The radial nerve was identified and protected. A pre-selected plate was contoured and introduced in the submuscular plane. The plate was placed in a proximal-lateral and distal-anterior position. Screws were inserted through stab incisions. The patients were followed for an average of 6 months. Functional recovery of the shoulder and elbow was assessed using the Constant and Mayo elbow performance score systems.
RESULTS: All incisions healed by first intention without complications and all the fractures went on to unite. All patients achieved good to excellent shoulder and elbow function.
CONCLUSION: The helical plate technique is a safe and effective method of treating humeral shaft fractures and has good functional outcome.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app