The utility of adding expiratory or decubitus chest radiographs to the radiographic evaluation of suspected pediatric airway foreign bodies.

STUDY OBJECTIVE: This study aimed to compare test characteristics of standard (lateral and posteroanterior or anteroposterior) chest radiographs with and without special views (expiratory or bilateral decubitus) in the emergency department evaluation of children with suspected airway foreign bodies.

METHODS: From 1997 to 2008, 328 patients with a suspected airway foreign body had standard and special view chest radiographs: 192 with left and right decubitus views, 133 with expiratory views, and 3 with both. Patients were excluded for cardiorespiratory disease, chest wall deformity, visible airway foreign bodies on standard views, or spontaneously expelled airway foreign bodies. After blinded radiologist review, standard plus special view test characteristics were compared to standard views.

RESULTS: Nine upper airway and 70 tracheobronchial airway foreign bodies were identified by direct visualization or bronchoscopy, and the remainder were ruled out by bronchoscopy (50 patients) or clinically (199 patients). The sensitivity and specificity of the radiographs were, respectively, decubitus cohort, standard views, 56% and 79% and standard+decubitus views, 56% and 64%; expiratory radiograph cohort, standard views, 33% and 70% and standard+expiratory views, 62% and 72%. For standard plus decubitus views versus standard views alone, the relative sensitivity was 1.0 (0.56/0.56; 95% confidence interval [CI] 0.81 to 1.23) and the relative 1-specificity was 1.76 (0.36/0.21; 95% CI 1.3 to 2.37). For standard plus expiratory views versus standard views alone, the relative sensitivity was 1.87 (0.62/0.33; 95% CI 1.23 to 2.83) and the relative 1-specificity was 0.93 (0.28/0.3; 95% CI 0.6 to 1.44).

CONCLUSION: The addition of decubitus to standard views increases false positives without increasing true positives and lacks clinical benefit. The addition of expiratory to standard views increases true positives without increasing false positives, but test accuracy remains low and the clinical benefit is uncertain.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app