Add like
Add dislike
Add to saved papers

Expandable Micro-motor Bur, design of a new device for least invasive extraction of broken teeth roots.

BACKGROUND: Extraction of a broken tooth root is often a traumatic experience for both the practitioner and the patient. To extract broken roots, generally invasive approaches as open window surgeries or mucoperiosteal flap and/or removal of buccal bone are performed.

PRESENTATION OF THE HYPOTHESIS: Expandable micro-motor bur (EMB) is a hypothetical design of a dental instrument proposed for removal of broken teeth roots that cannot be extracted by the routine closed methods and in which common instrumentations cannot afford to accomplish. Implication of EMB would introduce a new technique in removal of broken teeth roots in which surgical trauma is minimized and so post-extraction disorders. It would eliminate surgical invasion to the surrounding tissues; and also it would eliminate profound hand forces by the practitioner, consequently reduces stress for both the practitioner and the patient. It would eliminate high risk aftermaths such as operative morbidity (due to bone loss), maxillary sinus exposure and probable need for additional surgery as are indicative of some conventional open access approaches.

TESTING THE HYPOTHESIS: Further studies are needed to confirm its effect in clinical cases. The effectiveness of EMB should be verified firstly by animal experiments. The likelihood of its negative influence on nearby vascular and nerve system should be well evaluated.

IMPLICATIONS OF THE HYPOTHESIS: Implication of EMB would be of interest to both patients and the surgeon due to the following main achievements: a) no need for mucoperiosteal flap, hence preservation of soft tissue, b) no need for osteotomy, hence retention of buccal bone, c) less risk of sinus exposure, d) minimum chance of post operative infections due to eliminated surgeries in soft tissues and bones and e) in terms of esthetics, it will have a special meaning for immediate placement of dental implants. EMB's structural components include Bur head, Spacers and Bur base. A micro motor would power its spin. In contrast to conventional surgical approaches, EMB procedure is conservative. It is anticipated that EMB would provide less traumatic and least post-operative complications in extraction of broken teeth roots.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app