JOURNAL ARTICLE
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Quantifying diplopia with a questionnaire.

Ophthalmology 2013 July
PURPOSE: To report a diplopia questionnaire (DQ) with a data-driven scoring algorithm.

DESIGN: Cross-sectional study.

PARTICIPANTS: To optimize questionnaire scoring, 147 adults with diplopic strabismus completed both the DQ and the Adult Strabismus-20 (AS-20) health-related quality-of-life (HRQOL) questionnaire. To assess test-retest reliability, 117 adults with diplopic strabismus. To assess responsiveness to surgery, 42 adults (46 surgeries).

METHODS: The 10-item AS-20 function subscale score (scored 0-100) was defined as the gold standard for severity. A range of weights was assigned to the responses and the gaze positions (from equal weighting to greater weighting of primary and reading). Combining all response option weights with all gaze position weights yielded 382848 scoring algorithms. We then calculated 382848 Spearman rank correlation coefficients comparing each algorithm with the AS-20 function subscale score.

MAIN OUTCOME MEASURES: To optimize scoring, Spearman rank correlation coefficients (measuring agreement) between DQ scores and AS-20 function subscale scores. For test-retest reliability, 95% limits of agreement and intraclass correlation coefficient (ICC). For responsiveness, change in DQ score.

RESULTS: For the 382 848 possible scoring algorithms, correlations with AS-20 function subscale score ranged from -0.64 (best correlated) to -0.55. The best-correlated algorithm had response option weights of 5 for rarely, 50 for sometimes, and 75 for often, and gaze position weights of 40 for straight ahead in the distance, 40 for reading, 1 for up, 8 for down, 4 for right, 4 for left, and 3 for other, totaling 100. There was excellent test-retest reliability with an ICC of 0.89 (95% confidence interval, 0.84-0.92), and 95% limits of agreement were 30.9 points. The DQ score was responsive to surgery with a mean change of 51 ± 34 (P<0.001).

CONCLUSIONS: We have developed a data-driven scoring algorithm for the DQ, rating diplopia symptoms from 0 to 100. On the basis of correlations with HRQOL, straight-ahead and reading positions should be highly weighted. The DQ has excellent test-retest reliability and responsiveness, and may be useful in both clinical and research settings.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app