JOURNAL ARTICLE
OBSERVATIONAL STUDY
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Measurement of calprotectin in ascitic fluid to identify elevated polymorphonuclear cell count.

AIM: To evaluate the diagnostic capability of calprotectin in ascitic fluid for detecting a polymorphonuclear (PMN) cell count > 250/μL ascites.

METHODS: In this prospective observational study, a total of 130 ascites samples were analysed from 71 consecutive patients referred for paracentesis. Total and differential leukocyte cell counts were determined manually with a Neubauer chamber and gentian-violet stain. Calprotectin was measured in 1 mL ascetic fluid by enzyme-linked immunosorbent assay (ELISA) and a point-of-care (POC) lateral flow assay with the Quantum Blue(®) Reader (Bühlmann Laboratories). All measurements were carried out in a central laboratory by senior personnel blinded to patient history. A PMN count > 250/μL was the primary endpoint of the study. The diagnostic value of ascitic calprotectin measurement was assessed by comparing to the final diagnosis of each patient that had been adjudicated by investigators blinded to calprotectin values.

RESULTS: The PMN count was > 250/μL in 19 samples (14.6%) from 15 patients (21.1%) and varied widely among the study population (range 10-19 800/mL and 1-17 820/mL, respectively). Spontaneous bacterial peritonitis (SBP) was the final diagnosis in four patients (5.6%). All patients with PMN ≤ 250/μL had negative bacterial culture. PMN count was elevated in five patients with peritoneal carcinomatosis, three with lymphoma, one with neuroendocrine carcinoma, and two with secondary peritonitis due to abdominal perforation. PMN cell counts correlated with ascitic calprotectin values (Spearman's rho; r = 0.457 for ELISA, r = 0.473 for POC). A considerable range of ascitic calprotectin concentrations was detected by ELISA [median 0.43 μg/mL, interquartile range (IQR) 0.23-1.23 (range 0.10-14.93)] and POC [median 0.38 μg/mL, IQR 0.38-0.56 (range 0.38-13.31)]. Ascitic calprotectin levels were higher in samples with PMN > 250/μL, by both ELISA [median (IQR) 2.48 μg/mL (1.61-3.65) vs 0.10 μg/mL (0.10-0.36), P < 0.001] and POC [2.78 μg/mL (2.05-5.37) vs 0.38 μg/mL (0.38-0.41), P < 0.001]. The area under the receiver operating characteristics curve for identifying an elevated PMN count was 0.977 (95%CI: 0.933 to 0.995) for ELISA and 0.982 (95%CI: 0.942 to 0.997) for POC (P = 0.246 vs ELISA). Using the optimal cut-off value for ELISA (0.63 μg/mL), ascitic calprotectin had 94.8% sensitivity, 89.2% specificity, positive and negative likelihood ratios of 8.76 and 0.06 respectively, positive and negative predictive values of 60.0% and 99.0% respectively, and 90.0% overall accuracy. Using the optimal cut-off value for POC (0.51 μg/mL), the respective values were 100.0%, 84.7%, 6.53, 0.00, 52.8%, 100% and 87.7%. Correlation between ELISA and POC was excellent (r = 0.873, P < 0.001). The mean ± SD of the difference was -0.11 ± 0.48 μg/mL with limits of agreement of + 0.8 μg/mL (95%CI: 0.69 to 0.98) and -1.1 μg/mL (95%CI: -1.19 to -0.91).

CONCLUSION: Ascitic calprotectin reliably predicts PMN count > 250/μL, which may prove useful in the diagnosis of SBP, especially with a readily available bedside testing device.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app