COMPARATIVE STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Continuously moving table aorto-iliofemoral run-off contrast-enhanced magnetic resonance angiography: image quality analysis in comparison to the multistep acquisition.

Acta Radiologica 2014 April
BACKGROUND: Optimal vessel contrast is a prerequisite for vascular imaging. Consecutive stationary imaging of multiple fields of view is contrary to the continuous contrast material passage through the vascular tree. A continuous acquisition of a magnetic resonance (MR) sequence might overcome this limitation.

PURPOSE: To investigate the image quality of a continuously moving table (CMT) acquisition compared with the established multistep approach for contrast-enhanced magnetic resonance angiography (CE-MRA) of the aorto-iliofemoral run-off.

MATERIAL AND METHODS: Institutional review board approved this retrospective interindividual study of 60 consecutive patients referred to CE-MRA for peripheral arterial disease. Thirty patients underwent CE-MRA using the routine multistep acquisition and 30 patients were scanned using the CMT technique at 1.5 Tesla. All patients received a fixed contrast dose of 25 mL gadoterate meglumine. A quantitative analysis was performed to assess the relative contrast of 10 vascular segments from the proximal abdominal aorta to the distal calf arteries. A qualitative evaluation of three separate vascular regions (abdomen and pelvis, thighs, and calves) was performed. Two radiologists graded independently arterial vessel conspicuity, venous contamination, presence of artifacts, and diagnostic confidence on a 4-point scale. Overall scan time, including all localizer scans, was recorded. Statistical differences were tested using the Wilcoxon signed-rank test with Bonferroni correction.

RESULTS: No significant differences were found between the continuously moving table acquisition and the multistep acquisition with regard to the relative vascular contrast and the qualitative image criteria. The agreement between both readers was significant (Kendall tau rank correlation coefficient, 0.373). The absolute reader agreement was 71.4%. The mean overall scan time was 12 min 44 s for the CMT protocol and 21 min 41 s for the multistep protocol.

CONCLUSION: Aorto-iliofemoral run-off CE-MRA acquired with CMT technique provides a high image quality equivalent to a multistep technique at an overall scan time reduction of 41.3%.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app