A Comparative Evaluation of Fixation Techniques in Anterior Mandibular Fractures Using 2.0 mm Monocortical Titanium Miniplates Versus 2.4 mm Cortical Titanium Lag Screws.

OBJECTIVE: To compare the efficacy and surgical outcome of treatment of anterior mandibular fracture using either 2.0 mm titanium miniplate or 2.4 mm titanium lag screw technique.

MATERIALS AND METHODS: A total of 30 patients were managed by open reduction and internal fixation utilizing the miniplate and lag screw technique for fractures of anterior mandible. The patients were randomly divided into two groups. Group I: (15 patients) were treated with Leibinger, 2.0 mm titanium mini plates system with self-tapping screws and Group II: (15 patients) were treated with 2.4 mm cortical lag screw (Synthes). Intraoperatively duration of surgery was measured from the time incision was placed till the closure of wound. Subsequent follow up was done at 3, 6, 12, 24 weeks, postoperatively. During every follow up, patients were assessed clinically for malocclusion, neurosensory deficit, biting efficiency, implant failure, mal-union/non-union. Pre and postoperative radiographs were taken to assess the gap between fracture segments. Results were evaluated using Chi square and the unpaired t test.

RESULTS: In our study, the mean duration of surgery (hours) was 1.97 ± 0.52 for group I and 1.26 ± 0.55 for group II. The difference was found to be statistically significant (p value 0.001). i.e. more time was taken in case of surgery with mini-plates when compared to the lag screw. Short surgical procedure reduces the incidence of infectious complications, which significantly lowers the financial burden. The mean post-operative radiographic distance between all measuring points were considerably more in case of mini-plate group as compared to lag screw group. Lag screw group showed faster improvement in terms of biting efficiency as compared to mini-plate group which showed a tendency to masticate only medium hard food items by 24 weeks. In both groups, no postoperative malocclusion was noted. In initial weeks, neurosensory deficit was seen more in mini-plate group as compared to lag screw group but after six weeks all patients showed improvement in neurosensory function without any permanent nerve damage.

CONCLUSION: According to this prospective study, rigid internal fixation provided by lag screw technique for anterior mandibular fracture offers several advantages over conventional bone plating. It is an excellent means of achieving rapid and safe fixation which is followed by primary bone healing in anterior mandibular fractures, without any major complications.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app