Transoral parathyroid surgery--a new alternative or nonsense?

PURPOSE: In recent years, several endoscopic techniques have been explored in thyroid and parathyroid surgery, but only few gained acceptance among patients and surgeons. Based on extensive human cadaver and animal studies, we developed a technique for transoral partial parathyroidectomy (TOPP), which was performed for the first time in a patient with primary hyperparathyroidism (pHPT). We now report on results and the acceptance of this new technique 2 years after its implementation.

METHODS: A pilot study was initiated to recruit a total of 10 patients with benign sporadic pHPT and a preoperatively localized parathyroid adenoma eligible for initial parathyroidectomy. The study protocol was approved by the ethics committee, and an insurance for unforeseen complications and risks was procured. Data of all patients evaluated and operated were prospectively collected, and follow-up examinations were carried out for 19 months on average, which included clinical examinations; ultrasonography; Ear, Nose, and Throat (ENT) investigations; and blood testing.

RESULTS: Between January 2010 and May 2012, 75 patients with pHPT and a preoperative localized parathyroid adenoma were eligible for TOPP. After detailed information about the transoral procedure, only five (7 %) female patients consent to undergo TOPP. In three patients, a parathyroid adenoma could be removed via the transoral access, In two patients, the procedure had to be converted to the conventional technique. Median time until resection of a parathyroid adenoma was 122 min (range, 45-175). One patient had a transient recurrent laryngeal nerve palsy, while one patient suffered from a transient palsy of the right hypoglossal nerve and a slight but persisting dysgeusia. Three patients developed a hematoma of the mouth floor and swallowing problems. In four patients, the visual analog scale (VAS) pain score was high (>7) within the first 2 postoperative days.

CONCLUSIONS: Although TOPP is feasible, it is poorly accepted by patients and its complication rate is high. Thus, TOPP is nonsense with currently available devices.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app