BACKGROUND: Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint arthrodesis.
METHODS: First metatarsophalangeal joint arthrodesis using a crossed screw technique was performed on 11 paired, preserved cadaver first rays with two 4.0-mm triple-threaded, cannulated headless screws or two 4.0-mm partially threaded, cannulated lag screws. The constructs were tested to failure through dorsally directed cantilever bending.
RESULTS: The triple-threaded, cannulated headless screws displayed significantly greater bending stiffness (p=0.017) and failure load (p=0.040) during load-to-failure testing compared to the partially threaded, cannulated lag screws.
CONCLUSIONS: Triple-threaded, cannulated headless screws may be a viable alternative to partially threaded lag screws in first metatarsophalangeal arthrodesis.
METHODS: First metatarsophalangeal joint arthrodesis using a crossed screw technique was performed on 11 paired, preserved cadaver first rays with two 4.0-mm triple-threaded, cannulated headless screws or two 4.0-mm partially threaded, cannulated lag screws. The constructs were tested to failure through dorsally directed cantilever bending.
RESULTS: The triple-threaded, cannulated headless screws displayed significantly greater bending stiffness (p=0.017) and failure load (p=0.040) during load-to-failure testing compared to the partially threaded, cannulated lag screws.
CONCLUSIONS: Triple-threaded, cannulated headless screws may be a viable alternative to partially threaded lag screws in first metatarsophalangeal arthrodesis.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app