Journal Article
Multicenter Study
Observational Study
Randomized Controlled Trial
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Risk factors and morbidity associated with suboptimal instrument placement at instrumental delivery: observational study nested within the Instrumental Delivery & Ultrasound randomised controlled trial ISRCTN 72230496.

OBJECTIVES: To identify risk factors and morbidity associated with suboptimal instrument placement at instrumental delivery.

DESIGN: Observational study, nested within a randomised controlled trial.

SETTING: Two university-affiliated maternity hospitals.

SAMPLE: A cohort of 478 nulliparous women at term (≥37 weeks of gestation) undergoing instrumental delivery.

METHODS: Univariable and multivariable logistic regression analyses were performed.

MAIN OUTCOME MEASURES: Risk factors for suboptimal application of vacuum or forceps, maternal and neonatal morbidity, and the sequential use of instruments, second operator, and caesarean section following failed instrumental delivery.

RESULTS: Instrument placement was suboptimal in 138 of 478 (28.8%) deliveries. Factors associated with suboptimal instrument placement included fetal malposition (OR 2.44, 95% CI 1.62-3.66), mid-cavity station (OR 1.68, 95% CI 1.02-2.78), and forceps as the primary instrument (OR 2.01, 95% CI 1.33-3.04). Compared with optimal instrument placement, suboptimal placement was associated with prolonged hospital stay (adjusted OR 2.28, 95% CI 1.30-4.02) and neonatal trauma (adjusted OR 4.25, 95% CI 1.85-9.72). Suboptimal placement was associated with a greater use of sequential instruments (adjusted OR 3.99, 95% CI 1.94-8.23) and caesarean section for failed instrumental delivery (adjusted OR 3.81, 95% CI 1.10-13.16). The mean decision to delivery interval (DDI) was 4 minutes longer in the suboptimal group (95% CI 2.1-5.9 minutes).

CONCLUSIONS: Suboptimal instrument placement is associated with increased maternal and neonatal morbidity and procedural complications. Greater attention should be focused on instrument placement when training obstetricians for instrumental delivery.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app