Carbon dioxide field flooding reduces the hemodynamic effects of venous air embolism occurring in the sitting position.
Child's Nervous System : ChNS : Official Journal of the International Society for Pediatric Neurosurgery 2015 August
PURPOSE: Although the utility of the sitting position is undisputed for biomechanical and ergonomic reasons, it has been debated in recent years for its risks, particularly venous air embolism (VAE). In order to reduce the hemodynamic effect of VAE, we changed the composition of the surgical field air partially replacing nitrogen with carbon dioxide (CO2) that better dissolves in human tissues.
METHODS: First, we tested our method on a test dummy in the sitting position. Infrared CO2 sensors were placed close to the wound opening and on the facial mask of the surgeon. An oxygen sensor was connected to a computer for data recording (ALTAIR(®), MSA Safety). This model showed that 10 L/min CO2 flow provides efficient air displacement, maintaining safety for the surgeon. We reproduced the above-described surgical field environment in ten consecutive cases of posterior fossa surgery performed in the sitting position. A homogeneous group of ten patients operated in the sitting position with standard setting environment was used for control. We intraoperatively monitored VAE with trans-esophageal echocardiography (TEE), end-tidal CO2 (ETCO2), CO2 arterial pressure (PaCO2), and hemodynamic changes.
RESULTS: Although the percentage of VAE was 70% in both groups, hemodynamic effects occurred in 10% of cases in the study group and in 40% of cases in the control group.
CONCLUSIONS: Our preliminary study shows that a CO2-enriched sitting position surgical microenvironment significantly reduces the hemodynamic effects of VAE, more likely because arterial CO2 emboli are more soluble and consequently much better tolerated than air emboli.
METHODS: First, we tested our method on a test dummy in the sitting position. Infrared CO2 sensors were placed close to the wound opening and on the facial mask of the surgeon. An oxygen sensor was connected to a computer for data recording (ALTAIR(®), MSA Safety). This model showed that 10 L/min CO2 flow provides efficient air displacement, maintaining safety for the surgeon. We reproduced the above-described surgical field environment in ten consecutive cases of posterior fossa surgery performed in the sitting position. A homogeneous group of ten patients operated in the sitting position with standard setting environment was used for control. We intraoperatively monitored VAE with trans-esophageal echocardiography (TEE), end-tidal CO2 (ETCO2), CO2 arterial pressure (PaCO2), and hemodynamic changes.
RESULTS: Although the percentage of VAE was 70% in both groups, hemodynamic effects occurred in 10% of cases in the study group and in 40% of cases in the control group.
CONCLUSIONS: Our preliminary study shows that a CO2-enriched sitting position surgical microenvironment significantly reduces the hemodynamic effects of VAE, more likely because arterial CO2 emboli are more soluble and consequently much better tolerated than air emboli.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app