Percutaneous closure of inter-atrial communications (atrial septal defect and patent foramen ovale): single-centre experience and mid-term follow-up.

BACKGROUND: Percutaneous closure of atrial septal defect (ASD) and patent foramen ovale (PFO) are increasingly being performed. Effective closure rate depends on the anatomy of the interatrial septum and the device used, but its relationship with outcome is poorly described. This study aimed at evaluating: (1) effective ASD and PFO closure rate, (2) factors related with effective closure rate, and (3) factors related with mid-term outcome.

METHODS: All patients who underwent percutaneous ASD or PFO closure at Jessa Hospital Hasselt between April 2002 and February 2014 were enrolled. Closure rate was evaluated using consecutive contrast echocardiography studies. Adverse events were defined as a composite of all-cause mortality, hospitalization for heart failure, atrial arrhythmias and thrombo-embolic event.

RESULTS: One-hundred and two patients (52 +/- 12 y, 42% male, 75 PFO and 27 ASD) were included in the study. Moderate residual shunt was present in 6% and 10% 6 years after ASD and PFO closure, respectively. The presence of an aneurysmatic interatrial septum was associated with residual shunt after PFO closure (HR 0.57 95% CI 0.33-0.96; P=0.031). Pulmonary hypertension (HR 1.09 95% CI 1.01-1.17; P=0.017) and a history of atrial arrhythmias in ASD (HR 4.28 95% CI 1.06-17.40; P=0.046) and age at closure (HR 1.09 95% CI 1.02-1.16; P=0.012) in PFO patients were related with adverse events. The highest rate of adverse events was observed after placement of a Helex Septal Occluder. Amplatzer and Occlutech devices yielded higher effective closure rates.

CONCLUSIONS: Effective closure rates were acceptable 6 years after ASD and PFO closure. The presence of an aneurysmatic septum is associated with residual shunting after PFO closure. Pulmonary hypertension in ASD and older age at closure in PFO are associated with adverse outcome. Adverse events are more frequent with the Helex occluder and effective closure rate depends on the device used.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app