Add like
Add dislike
Add to saved papers

The use of dried blood spot sampling for the measurement of HbA1c: a cross-sectional study.

BACKGROUND: The use of dried blood spot (DBS) sampling is an alternative to traditional venous blood collection, and particularly useful for people living in rural and remote areas, and for those who are infirm, house-bound or time-poor. The objective of this study was to assess whether the measurement of glycated haemoglobin A1c (HbA1c) in DBS samples provided comparative and acceptably precise results.

METHODS: Venous and capillary blood samples were collected from 115 adult participants. After proper instruction, each participant punctured his/her own finger and collected capillary blood samples on pieces of a proprietary cellulose filter paper. Each filter paper was subsequently placed inside a breathable envelope, stored at room temperature, and processed on the same day (D0), four (D4), seven (D7) and fourteen (D14) days after collection. HbA1c was measured in duplicates/triplicates in whole venous blood (WB), capillary blood (capDBS) and venous blood placed on the matrix paper (venDBS), by turbidimetric inhibition immunoassay. Intra-assay coefficients of variation (CV) were calculated. DBS values were compared to WB results using linear regression, Bland-Altman plots and cross-validation models.

RESULTS: Eleven and 56 patients had type 1 and type 2 diabetes mellitus, respectively. Mean HbA1c levels were 6.22 ± 1.11 % for WB samples (n = 115). The median intra-assay CV was lower than 3 % for WB and capDBS on all days. Results from capDBS and venDBS showed high correlation and agreement to WB results, with narrow 95 % limits of agreement (except for results from D14 samples), as observed in Bland-Altman plots. When capDBS values were applied to equations derived from regression analyses, results approached those of WB values. A cross-validation model showed that capDBS results on D0, D4 and D7 were close to the WB results, with prediction intervals that were narrow enough to be clinically acceptable.

CONCLUSIONS: The measurement of HbA1c from DBS samples provided results that were comparable to results from WB samples, if measured up to seven days after collection. Intra-assay coefficients of variation were low, results were in agreement with the gold-standard, and prediction intervals were clinically acceptable. The measurement of HbA1c through DBS sampling may be considered in situations where traditional venipuncture is not available.

TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ID ACTRN12613000769785.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app