Orbital color Doppler ultrasound as noninvasive tool in the diagnosis of anterior-draining carotid-cavernous fistula.
La Radiologia Medica 2016 April
PURPOSE: To investigate the role of orbital color Doppler ultrasound (OCDUS) in the diagnosis of carotid-cavernous fistula (CCF) with anterior drainage and particularly whether a negative OCDUS could avoid an invasive diagnostic cerebral angiography (DSA).
MATERIALS AND METHODS: Twenty-two consecutive patients with ophthalmic signs suspecting CCF were submitted to ophthalmologic examination, OCDUS and DSA. CCF diagnosis with OCDUS was based on the finding of a reversed, arterialized and low-resistive-index (RI <0.5) blood flow in the superior ophthalmic vein (SOV). Sensibility, specificity, PPV, NPV, and accuracy of OCDUS were calculated considering both patients and eyes, using DSA as gold standard.
RESULTS: DSA demonstrated 20 CCFs in 18 patients. Considering the patients, in 18/22 CCF diagnosis was positive at OCDUS and DSA while 4/22 were negative at both. Considering the eyes, in 24/43 CCF diagnosis was positive at both DSA and OCDUS (total eyes = 43, due to one case of SOV thrombosis). In 19/43 eyes diagnosis was negative at both OCDUS and DSA. So sensitivity, specificity, PPV, NPV, and accuracy of OCDUS in the patients and eyes analysis were all 100 %.
CONCLUSIONS: OCDUS is a reliable, noninvasive tool in the diagnosis of CCF; a negative OCDUS could avoid an invasive DSA in patients suspected for anterior-draining CCF.
MATERIALS AND METHODS: Twenty-two consecutive patients with ophthalmic signs suspecting CCF were submitted to ophthalmologic examination, OCDUS and DSA. CCF diagnosis with OCDUS was based on the finding of a reversed, arterialized and low-resistive-index (RI <0.5) blood flow in the superior ophthalmic vein (SOV). Sensibility, specificity, PPV, NPV, and accuracy of OCDUS were calculated considering both patients and eyes, using DSA as gold standard.
RESULTS: DSA demonstrated 20 CCFs in 18 patients. Considering the patients, in 18/22 CCF diagnosis was positive at OCDUS and DSA while 4/22 were negative at both. Considering the eyes, in 24/43 CCF diagnosis was positive at both DSA and OCDUS (total eyes = 43, due to one case of SOV thrombosis). In 19/43 eyes diagnosis was negative at both OCDUS and DSA. So sensitivity, specificity, PPV, NPV, and accuracy of OCDUS in the patients and eyes analysis were all 100 %.
CONCLUSIONS: OCDUS is a reliable, noninvasive tool in the diagnosis of CCF; a negative OCDUS could avoid an invasive DSA in patients suspected for anterior-draining CCF.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app