Neonatal complications associated with use of fetal scalp electrode: a retrospective study.

OBJECTIVES: To estimate the incidence and risk of complications associated with a fetal scalp electrode and to determine whether its application in the setting of operative vaginal delivery was associated with increased neonatal morbidity.

DESIGN: Retrospective cohort study.

SETTING: Twelve clinical centers with 19 hospitals across nine American Congress of Obstetricians and Gynecologists US districts.

POPULATION: Women in the USA.

METHODS: We evaluated 171 698 women with singleton deliveries ≥ 23 weeks of gestation in a secondary analysis of the Consortium on Safe Labor study between 2002 and 2008, after excluding conditions that precluded fetal scalp electrode application such as prelabour caesarean delivery. Secondary analysis limited to operative vaginal deliveries ≥ 34 weeks of gestation was also performed.

MAIN OUTCOME MEASURES: Incidences and adjusted odds ratios with 95% confidence intervals of neonatal complications were calculated, controlling for maternal characteristics, delivery mode and pregnancy complications.

RESULTS: Fetal scalp electrode was used in 37 492 (22%) of deliveries. In non-operative vaginal delivery, fetal scalp electrode was associated with increased risk of injury to scalp due to birth trauma (1.2% versus 0.9%; adjusted odds ratios 1.62; 95% confidence intervals 1.41-1.86) and cephalohaematoma (1.0% versus 0.9%; adjusted odds ratios 1.57; 95% confidence intervals 1.36-1.83). Neonatal complications were not significantly different comparing fetal scalp electrode with vacuum-assisted vaginal delivery and vacuum-assisted vaginal delivery alone or comparing fetal scalp electrode with forceps-assisted vaginal delivery and forceps-assisted vaginal delivery alone.

CONCLUSIONS: We found increased neonatal morbidity with fetal scalp electrode though the absolute risk was very low. It is possible that these findings reflect an underlying indication for its use. Our findings support the use of fetal scalp electrodes when clinically indicated.

TWEETABLE ABSTRACT: Neonatal risks associated with fetal scalp electrode use were low (injury to scalp 1.2% and cephalohaematoma 1.0%).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app