Add like
Add dislike
Add to saved papers

Volar, Intramedullary, and Percutaneous Fixation of Distal Radius Fractures.

Background The management of extra-articular distal radius fractures is highly variable, with no clear consensus regarding their optimal management. Purpose To assess comparatively the biomechanical stability of Kirschner wire (K-wire) fixation, volar plating, and intramedullary nailing for unstable, extra-articular distal radius fractures with both (1) constant and (2) cyclical axial compression, simulating forces experienced during early postoperative rehabilitation. Methods Twenty-six volar locking plate, intramedullary nail, and K-wire bone-implant constructs were biomechanically assessed using an unstable extra-articular distal radius bone model. Bone implant models were created for each type of construct. Three samples from each construct underwent compressive axial loading until fixation failure. The remaining samples from each construct underwent fatigue testing with a 50-N force for 2,000 cycles followed by repeat compressive axial loading until fixation failure. Results Axial loading revealed the volar plate was significantly stiffer than the intramedullary nail and K-wire constructs. Both the volar plate and intramedullary nail required greater than 300 N of force for fixation failure, while the K-wire construct failed at less than 150 N. Both the volar plate and intramedullary nail demonstrated less than 1 mm of displacement during cyclic loading, while the K-wire construct displaced greater than 3 mm. Postfatigue testing demonstrated the volar plate was stiffer than the intramedullary nail and K-wire constructs, and both the volar plate and intramedullary nail required greater than 300 N of force for fixation failure while the K-wire construct failed at less than 150 N. Conclusions Volar plating of unstable extra-articular distal radius fractures is biomechanically stiffer than K-wire and intramedullary fixation. Both the volar plate and intramedullary nail demonstrated the necessary stability and stiffness to maintain anatomic reduction during the postoperative rehabilitation period. Clinical Relevance Both the volar plate and intramedullary nail demonstrated the necessary biomechanical stability to maintain postoperative reduction in extra-articular distal radius fractures, warranting further clinical comparison.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app