Individually tailored contrast enhancement in CT pulmonary angiography.

OBJECTIVE: The purpose was to evaluate individually shaped contrast media (CM) delivery in CT pulmonary angiography (CTPA) for suspected pulmonary embolism (PE).

METHODS: 100 consecutive emergency patients with clinical suspicion of PE were evaluated. High-pitch CTPA was performed on a second-generation dual-source CT using the following parameters: 100 kV, 200-250 mAsref, rotation time 0.28 s, 128 × 0.6 mm col. and image reconstruction 1.0/0.8 mm (B30f). Group 1 (n = 50) then received a fixed CM bolus (300 = mgI ml(-1), volume = 90 ml and flow rate = 6 ml s(-1)); Group 2 (n = 50) received a body weight-adapted CM bolus determined by dedicated contrast injection software. For analysis, groups were further subdivided into low-weight (40-75 kg) and high-weight (76-117 kg) groups. Technical image quality was graded using a four-point Likert scale (1 = non-diagnostic; 2 = diagnostic; 3 = good and 4 = excellent image quality) at the level of the pulmonary trunk and pulmonary arteries. Objective image quality analysis was performed by measuring contrast enhancement in Hounsfield units (HU) at the same levels. Attenuation levels > 180 HU were considered diagnostic.

RESULTS: All examinations were graded as diagnostic at each level. The individual minimum pulmonary attenuation was 184 and 270 HU for Group 1 and 2, respectively. Mean attenuation was as follows: Group 1: 475 ± 105 HU (40-75 kg) and 402 ± 115 HU (76-117 kg), p < 0.03. Group 2: 424 ± 76 HU (40-75 kg) and 418 ± 100 HU (76-117 kg), p = 0.8. For Group 2, CM volumes were: 55 ± 5 ml (40-75 kg) and 66 ± 5 ml (76-117 kg), leading to 16-51% CM reduction.

CONCLUSION: Even under emergency conditions, individualized CM protocols can provide diagnostic and robust image quality in CTPA for PE with a substantial reduction of CM volume for lower weight patients, compared with a fixed CM protocol.

ADVANCES IN KNOWLEDGE: CM volume can substantially be reduced by using individualized CM protocols in CT angiography for PE without compromising the diagnostic image quality.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app