Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Effect of Balloon:Annulus Ratio on Incidence of Pulmonary Insufficiency Following Valvuloplasty.

OBJECTIVE: Pulmonary insufficiency following balloon valvuloplasty for pulmonary valve stenosis has been shown to result in right ventricular dilation, which may necessitate pulmonary valve replacement. This study investigates the consequences of employing a more conservative balloon:annulus ratio of ≤1.2 against the currently used ratios of >1.2. The aim of the study was to evaluate whether a more conservative balloon:annulus ratio would maintain procedural success with adequate relief of the pulmonary valve gradient, while minimizing pulmonic insufficiency.

DESIGN: Procedural data were collected on cases considered for balloon valvuloplasty for congenital pulmonic stenosis at Rady Children's Hospital, San Diego between March 31, 2003 and April 9, 2014. The study includes 98 patients whose median age at the time of procedure was 3.6 months (range: 1 day to 271 months); median follow-up was 15.2 months (range 24 days to 106 months). The subjects were divided into two groups based on their balloon:annulus ratio: ≤1.2 (n = 67) and >1.2 (n = 31).

RESULTS: The difference in pulmonary gradient reduction-the marker of procedural success-was not significant between the two groups (P = .33). Although both groups had an increase in pulmonary valve insufficiency from baseline, the ≤1.2 group had significantly less insufficiency compared to the >1.2 group (P = .008). Reintervention rates were not statistically significant between both groups (P = .89).

CONCLUSION: Performing pulmonary balloon valvuloplasty with a balloon:annulus ratio of ≤1.2 produces significantly less pulmonary insufficiency than a ratio of >1.2 without reducing procedure efficacy.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app