JOURNAL ARTICLE
OBSERVATIONAL STUDY
Add like
Add dislike
Add to saved papers

The Effect of Postoperative Face-Down Positioning and of Long- versus Short-Acting Gas in Macular Hole Surgery: Results of a Registry-Based Study.

Ophthalmology 2016 May
PURPOSE: To determine whether sulfur hexafluoride (SF6) gas is noninferior to longer-acting gases in macular hole surgery and whether withholding postoperative face-down positioning (FDP) is noninferior to FDP.

DESIGN: Registry-style, prospective, nonrandomized, observational cohort study.

PARTICIPANTS: Patients with idiopathic macular holes undergoing primary surgery.

METHODS: Surgeons were invited to submit clinical details of all macular hole cases receiving surgery. Baseline demographic and clinical information were collected, as well as details of surgical intervention and postoperative posturing advice. Primary follow-up data were collected 3 months postoperatively.

MAIN OUTCOME MEASURES: Macular hole closure at 3 months. A noninferiority approach was used, with a noninferiority margin set at 5% decreased frequency of success.

RESULTS: A total of 2456 eyes of 2367 patients were included in the study. Outcomes were available in 94.9% of cases (2330/2456). The rate of macular hole closure was 95.0% (2214/2330). Sulfur hexafluoride gas was found to be noninferior to longer-acting gases (95% confidence interval [CI] for adjusted effect on success, -1.76 to +2.25), and noninferiority was demonstrated regardless of macular hole size. Although withholding FDP was found to be noninferior to FDP for the study population as a whole (95% CI for adjusted effect on success, -4.21 to +0.64), the result was inconclusive in holes >400 μm in diameter (95% CI, -9.31 to +1.04). Lack of internal limiting membrane (ILM) peel, increasing hole size, hole duration ≥9 months, increasing age, and 20-gauge surgery all were associated with lower odds of success. Vitreous attachment to the hole margin was not associated with outcome when corrected for hole size, and combined phacovitrectomy surgery was not observed to affect the odds of success in phakic eyes.

CONCLUSIONS: Sulfur hexafluoride gas tamponade was noninferior to longer-acting gases in the surgical management of macular hole. Withholding FDP was noninferior to FDP in holes ≤400 μm in diameter. In holes >400 μm in diameter, noninferiority of withholding FDP could not be concluded. We would advise caution if posturing is withheld in this group on the basis of the results of this study and of others.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app