Add like
Add dislike
Add to saved papers

Application value of diffusion weighted whole body imaging with background body signal suppression in monitoring the response to treatment of bone marrow involvement in lymphoma.

PURPOSE: To investigate the application value of diffusion weighted whole body imaging with background body signal suppression (DWIBS) in monitoring the response to treatment of bone marrow involvement in lymphoma.

MATERIALS AND METHODS: Twenty-one lymphoma patients with bone marrow involvement underwent 1.5 Tesla DWIBS before chemotherapy and after the second chemotherapy session (median interval, 8 weeks; range 7-11 weeks). Apparent diffusion coefficient (ADC) values of bone marrow lesions were measured before and after treatment. The difference in ADC values before and after treatment in responders and nonresponders was analyzed.

RESULTS: Seventy-three cases of bone marrow lesions were diagnosed in 21 lymphoma patients before the treatment. After the second chemotherapy session, 18 patients (57 lesions) and 3 patients (9 lesions) were categorized into the responder and nonresponder group, respectively. The mean pretreatment ADC value of all lesions was 0.90 ± 0.39 × 10-3 mm2 /s, of which the mean ADC values of the responder group and nonresponder group were 0.92 ± 0.40 × 10-3 mm2 /s and 0.79 ± 0.29 × 10-3 mm2 /s, respectively (between-group difference: t = -0.94; P = 0.351). The posttreatment ADC value of the responder group significantly increased (66.39% ± 83.11%; P < 0.001) while the posttreatment ADC value of the nonresponder group slightly increased (5.32% ± 17.31%). The difference in the rate of change of ADC values in the responder and nonresponder groups before and after the treatment was significant (P < 0.05).

CONCLUSION: DWIBS in combination with the measurement of ADC values enabled a good short-term response evaluation for bone marrow involvement in lymphoma. However, the pretreatment ADC value indicated no significant predictive value for responses to the treatment. J. Magn. Reson. Imaging 2016;44:1522-1529.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app