A Randomized Trial of Factor VIII and Neutralizing Antibodies in Hemophilia A.

BACKGROUND: The development of neutralizing anti-factor VIII alloantibodies (inhibitors) in patients with severe hemophilia A may depend on the concentrate used for replacement therapy.

METHODS: We conducted a randomized trial to assess the incidence of factor VIII inhibitors among patients treated with plasma-derived factor VIII containing von Willebrand factor or recombinant factor VIII. Patients who met the eligibility criteria (male sex, age <6 years, severe hemophilia A, and no previous treatment with any factor VIII concentrate or only minimal treatment with blood components) were included from 42 sites.

RESULTS: Of 303 patients screened, 264 underwent randomization and 251 were analyzed. Inhibitors developed in 76 patients, 50 of whom had high-titer inhibitors (≥5 Bethesda units). Inhibitors developed in 29 of the 125 patients treated with plasma-derived factor VIII (20 patients had high-titer inhibitors) and in 47 of the 126 patients treated with recombinant factor VIII (30 patients had high-titer inhibitors). The cumulative incidence of all inhibitors was 26.8% (95% confidence interval [CI], 18.4 to 35.2) with plasma-derived factor VIII and 44.5% (95% CI, 34.7 to 54.3) with recombinant factor VIII; the cumulative incidence of high-titer inhibitors was 18.6% (95% CI, 11.2 to 26.0) and 28.4% (95% CI, 19.6 to 37.2), respectively. In Cox regression models for the primary end point of all inhibitors, recombinant factor VIII was associated with an 87% higher incidence than plasma-derived factor VIII (hazard ratio, 1.87; 95% CI, 1.17 to 2.96). This association did not change in multivariable analysis. For high-titer inhibitors, the hazard ratio was 1.69 (95% CI, 0.96 to 2.98). When the analysis was restricted to recombinant factor VIII products other than second-generation full-length recombinant factor VIII, effect estimates remained similar for all inhibitors (hazard ratio, 1.98; 95% CI, 0.99 to 3.97) and high-titer inhibitors (hazard ratio, 2.59; 95% CI, 1.11 to 6.00).

CONCLUSIONS: Patients treated with plasma-derived factor VIII containing von Willebrand factor had a lower incidence of inhibitors than those treated with recombinant factor VIII. (Funded by the Angelo Bianchi Bonomi Foundation and others; ClinicalTrials.gov number, NCT01064284; EudraCT number, 2009-011186-88.).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app