We have located links that may give you full text access.
The radiologic assessment of posterior ligamentous complex injury in patients with thoracolumbar fracture.
European Spine Journal 2017 May
PURPOSES: To discuss whether radiologic parameters are closely related to posterior ligamentous complex (PLC) injury identified by magnetic resonance imaging (MRI).
METHODS: One hundred and five thoracolumbar fracture (T11-L2) patients were retrospectively analyzed in the study. The patients were divided into different groups by the status of the PLC on MRI: intact, incompletely ruptured and ruptured. The radiographic parameters included the anterior edge-inferior endplate angle (AEIEA), the anterior edge displacement (AED), the Cobb angle (CA), the region angle (RA), the sagittal index (SI), local kyphosis (LK), the anterior/posterior vertebral height ratio (A/P ratio), the anterior vertebral height ratio (AVH ratio), and bony fragment in front of the fractured vertebra (BFOFV). T test, Pearson's Chi-square and multivariate logistic regression were calculated for the variables.
RESULTS: Supraspinous ligament (SSL) rupture versus intact was not only associated with the occurrence of AEIEA <70°, LK >25° and BFOFV, but also with increased AED (9.89 ± 3.12 mm and 9.34 ± 3.36 mm, P = 0.034), RA (9.52 ± 3.93° versus 7.91 ± 3.99°, P = 0.042), and LK (23.98 ± 5.88° versus 15.55 ± 5.28°, P = 0.021). The indications for interspinous ligament (ISL) injury included AEIEA <75°, AEIEA <70° (P = 0.004 and P < 0.001, respectively), increased AED (P = 0.010), LK >25° (P = 0.024), AVH (P < 0.001), and BFOFV (P < 0.001). Multivariate logistic regression analysis revealed that AEIEA <70° and BFOFV were high risk factors for SSL rupture [standard partial regression coefficients (betas) were 0.439 and 0.408, P = 0.003 and 0.001, respectively] and ISL rupture (betas were 0.548 and 0.494, P = 0.028 and 0.001, respectively). Increased AED and LK >25° were also related to either ISL rupture (P = 0.035 and 0.001, respectively) or SSL rupture (P = 0.014 and 0.008, respectively).
CONCLUSION: Our data may prove useful in a preliminary assessment of the PLC integrity based on plain radiographic imaging. We show that radiologic indications, such as AEIEA <70°, BFOFV, LK >25°, and increased AED, are correlated with ISL or SSL rupture, while RA, CA, SI, A/P ratio, and AVH ratio are not.
METHODS: One hundred and five thoracolumbar fracture (T11-L2) patients were retrospectively analyzed in the study. The patients were divided into different groups by the status of the PLC on MRI: intact, incompletely ruptured and ruptured. The radiographic parameters included the anterior edge-inferior endplate angle (AEIEA), the anterior edge displacement (AED), the Cobb angle (CA), the region angle (RA), the sagittal index (SI), local kyphosis (LK), the anterior/posterior vertebral height ratio (A/P ratio), the anterior vertebral height ratio (AVH ratio), and bony fragment in front of the fractured vertebra (BFOFV). T test, Pearson's Chi-square and multivariate logistic regression were calculated for the variables.
RESULTS: Supraspinous ligament (SSL) rupture versus intact was not only associated with the occurrence of AEIEA <70°, LK >25° and BFOFV, but also with increased AED (9.89 ± 3.12 mm and 9.34 ± 3.36 mm, P = 0.034), RA (9.52 ± 3.93° versus 7.91 ± 3.99°, P = 0.042), and LK (23.98 ± 5.88° versus 15.55 ± 5.28°, P = 0.021). The indications for interspinous ligament (ISL) injury included AEIEA <75°, AEIEA <70° (P = 0.004 and P < 0.001, respectively), increased AED (P = 0.010), LK >25° (P = 0.024), AVH (P < 0.001), and BFOFV (P < 0.001). Multivariate logistic regression analysis revealed that AEIEA <70° and BFOFV were high risk factors for SSL rupture [standard partial regression coefficients (betas) were 0.439 and 0.408, P = 0.003 and 0.001, respectively] and ISL rupture (betas were 0.548 and 0.494, P = 0.028 and 0.001, respectively). Increased AED and LK >25° were also related to either ISL rupture (P = 0.035 and 0.001, respectively) or SSL rupture (P = 0.014 and 0.008, respectively).
CONCLUSION: Our data may prove useful in a preliminary assessment of the PLC integrity based on plain radiographic imaging. We show that radiologic indications, such as AEIEA <70°, BFOFV, LK >25°, and increased AED, are correlated with ISL or SSL rupture, while RA, CA, SI, A/P ratio, and AVH ratio are not.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app