The effect of implementing an automated oxygen control on oxygen saturation in preterm infants.
Archives of Disease in Childhood. Fetal and Neonatal Edition 2017 September
OBJECTIVE: To evaluate the effect of implementing automated oxygen control as routine care in maintaining oxygen saturation (SpO2 ) within target range in preterm infants.
METHODS: Infants <30 weeks gestation in Leiden University Medical Centre before and after the implementation of automated oxygen control were compared. The percentage of time spent with SpO2 within and outside the target range (90-95%) was calculated. SpO2 values were collected every minute and included for analysis when infants received extra oxygen.
RESULTS: In a period of 9 months, 42 preterm infants (21 manual, 21 automated) were studied. In the automated period, the median (IQR) time spent with SpO2 within target range increased (manual vs automated: 48.4 (41.5-56.4)% vs 61.9 (48.5-72.3)%; p<0.01) and time SpO2 >95% decreased (41.9 (30.6-49.4)% vs 19.3 (11.5-24.5)%; p<0.001). The time SpO2 <90% increased (8.6 (7.2-11.7)% vs 15.1 (14.0-21.1)%; p<0.0001), while SpO2 <80% was similar (1.1 (0.4-1.7)% vs 0.9 (0.5-2.1)%; ns).
CONCLUSIONS: During oxygen therapy, preterm infants spent more time within the SpO2 target range after implementation of automated oxygen control, with a significant reduction in hyperoxaemia, but not hypoxaemia.
METHODS: Infants <30 weeks gestation in Leiden University Medical Centre before and after the implementation of automated oxygen control were compared. The percentage of time spent with SpO2 within and outside the target range (90-95%) was calculated. SpO2 values were collected every minute and included for analysis when infants received extra oxygen.
RESULTS: In a period of 9 months, 42 preterm infants (21 manual, 21 automated) were studied. In the automated period, the median (IQR) time spent with SpO2 within target range increased (manual vs automated: 48.4 (41.5-56.4)% vs 61.9 (48.5-72.3)%; p<0.01) and time SpO2 >95% decreased (41.9 (30.6-49.4)% vs 19.3 (11.5-24.5)%; p<0.001). The time SpO2 <90% increased (8.6 (7.2-11.7)% vs 15.1 (14.0-21.1)%; p<0.0001), while SpO2 <80% was similar (1.1 (0.4-1.7)% vs 0.9 (0.5-2.1)%; ns).
CONCLUSIONS: During oxygen therapy, preterm infants spent more time within the SpO2 target range after implementation of automated oxygen control, with a significant reduction in hyperoxaemia, but not hypoxaemia.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app