Transcatheter Mitral Valve Implantation Using the HighLife System.

OBJECTIVES: This study is the first report of 2 cases of HighLife (HighLife, Paris, France) implantation in humans.

BACKGROUND: Transcatheter mitral valve implantation represents a promising approach to treating mitral regurgitation in patients at increased risk of perioperative mortality. The HighLife transcatheter mitral valve is a 2-component system. The valve is implanted in the mitral position and is anchored by interacting and then reaching an equilibrium position with a previously positioned subannular implant.

METHODS: The procedures were successfully performed in a 69-year-old man and a 65-year-old woman with severe functional mitral regurgitation. Both patients were in New York Heart Association functional class IV heart failure with depressed left ventricular ejection fraction and additional comorbidities.

RESULTS: The valve was implanted uneventfully in both patients. General anesthesia was used. The subannular implant was deployed through the transfemoral access, whereas the transcatheter mitral valve was released using the transapical access. Patients maintained hemodynamically stable. There were no intraoperative complications. Acutely, post-procedural echocardiograms demonstrated excellent prosthetic valve function with a low transvalvular gradient and no paravalvular leak and left ventricular outflow tract obstruction. Both patients had mild intraprosthetic regurgitation. Patient #1 survived at 5-months follow-up in New York Heart Association functional class II with excellent prosthesis performance. Patient #2 expired 4 days after a technically successful procedure, because the left ventricle did not tolerate the reduction of mitral regurgitation and despite a high dose of inotropic agents the left ventricular function rapidly deteriorated.

CONCLUSIONS: Transcatheter mitral valve implantation using the 2-component HighLife system is technically feasible and can be performed safely. Early hemodynamic performance of the prosthesis was excellent.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app