Intraobserver and interobserver reliability assessment of tibial plateau fracture classification systems.
Joint Diseases & related Surgery 2017 December
OBJECTIVES: This study aims to assess the intra- and interobserver reliability of commonly used tibial plateau fracture classification systems.
PATIENTS AND METHODS: This retrospective cohort study included computed tomography (CT) and plain radiographic images (lateral and anteroposterior X-rays) of 60 patients (40 males, 20 females; mean age 45.9 years; range 18 to 80 years) who presented to two orthopaedic clinics between January 2011 and January 2015 with unilateral tibial plateau fractures. All plain X-rays (XR) and CT images were evaluated by four observers on two separate occasions, 1.5 months apart. All fractures were classified according to the Arbeitsgemeinschaft für Osteosynthesefragen-Orthopaedic Trauma Association (AO-OTA), Schatzker, Hohl and Moore, Luo and revised Duparc systems. Intraobserver reliability was measured with Cohen's kappa (κ) coefficient and interobserver reliability with Fleiss' kappa coefficient.
RESULTS: When Schatzker classification was performed, interobserver reliability was in moderate level for (κ=0.51) for XR and in substantial level for CT (κ=0.61). When AO/OTA classification was used, interobserver reliability was in moderate level for both methods of diagnosis (κXR=0.43 and κCT=0.54, respectively). In the Hohl and Moore classification, the interobserver reliability was also moderate for both methods of diagnosis (κXR=0.45 and κCT=0.51, respectively). Revised Duparc classification showed the lowest interobserver reliability ranging from fair to moderate level (κXR=0.27-0.55 and κCT=0.44-0.61). Interobserver reliability for Luo classification was κCT=0.47. Intraobserver reliability for CT in Luo classification was in substantial level for observers 1, 2 and 3 (κCT=0.67-0.71) and in perfect level for observer 4 (κCT=0.84). Intraobserver reliability was in substantial level in Schatzker classification and in moderate level at the other classifications.
CONCLUSION: Among the classification systems compared in this study, Schatzker was the most reliable particularly when CT was used. On the other hand, revised Duparc classification presented the worse reliability results due to its complexity and different morphological subtypes.
PATIENTS AND METHODS: This retrospective cohort study included computed tomography (CT) and plain radiographic images (lateral and anteroposterior X-rays) of 60 patients (40 males, 20 females; mean age 45.9 years; range 18 to 80 years) who presented to two orthopaedic clinics between January 2011 and January 2015 with unilateral tibial plateau fractures. All plain X-rays (XR) and CT images were evaluated by four observers on two separate occasions, 1.5 months apart. All fractures were classified according to the Arbeitsgemeinschaft für Osteosynthesefragen-Orthopaedic Trauma Association (AO-OTA), Schatzker, Hohl and Moore, Luo and revised Duparc systems. Intraobserver reliability was measured with Cohen's kappa (κ) coefficient and interobserver reliability with Fleiss' kappa coefficient.
RESULTS: When Schatzker classification was performed, interobserver reliability was in moderate level for (κ=0.51) for XR and in substantial level for CT (κ=0.61). When AO/OTA classification was used, interobserver reliability was in moderate level for both methods of diagnosis (κXR=0.43 and κCT=0.54, respectively). In the Hohl and Moore classification, the interobserver reliability was also moderate for both methods of diagnosis (κXR=0.45 and κCT=0.51, respectively). Revised Duparc classification showed the lowest interobserver reliability ranging from fair to moderate level (κXR=0.27-0.55 and κCT=0.44-0.61). Interobserver reliability for Luo classification was κCT=0.47. Intraobserver reliability for CT in Luo classification was in substantial level for observers 1, 2 and 3 (κCT=0.67-0.71) and in perfect level for observer 4 (κCT=0.84). Intraobserver reliability was in substantial level in Schatzker classification and in moderate level at the other classifications.
CONCLUSION: Among the classification systems compared in this study, Schatzker was the most reliable particularly when CT was used. On the other hand, revised Duparc classification presented the worse reliability results due to its complexity and different morphological subtypes.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app