We have located links that may give you full text access.
Permanent Versus Bioresorbable Implants in Orbital Floor Blowout Fractures.
Ophthalmic Plastic and Reconstructive Surgery 2018 Februrary 7
PURPOSE: To compare the outcomes of bioresorbable and permanent implants in the reconstruction of isolated orbital floor blowout fractures.
METHODS: Retrospective series of all patients who had orbital floor fracture repair in a single tertiary trauma center from January 2005 to December 2014. The authors reviewed the case notes and CT scans of patients with orbital floor fracture repair with either bioresorbable or permanent implants. Main outcome measures were enophthalmos, diplopia, and ocular motility restriction 1.5 years after fracture repair. Implant-related complications were collected for analysis.
RESULTS: There were a total of 88 patients in our study. Bioresorbable implants were used in 48 patients (54.5%) while 40 patients had permanent implants (45.5%). The authors analyzed the implants used in various sizes of orbital fractures: small (<13.3 mm), medium (13.3-20 mm), and large (>20 mm). One and a half years after fracture repair, both groups had comparable clinical outcomes (n = 2 and n = 0 for diplopia for permanent and bioresorbable implant groups, respectively, n = 0 for enophthalmos for both groups and n = 1 for ocular motility limitation for both groups) overall and across all fracture sizes.
CONCLUSION: Bioresorbable implants degrade after fracture healing through hydrolysis and promote the gradual transfer of functional forces to healing bone during its disintegration. The clinical outcomes of diplopia, enophthalmos, and ocular motility restriction associated with the use of resorbable implants are comparable to that of permanent implants for all fracture sizes. Their study shows that bioresorbable and permanent implants are equally safe and effective for the treatment of patients with isolated orbital floor blowout fractures.
METHODS: Retrospective series of all patients who had orbital floor fracture repair in a single tertiary trauma center from January 2005 to December 2014. The authors reviewed the case notes and CT scans of patients with orbital floor fracture repair with either bioresorbable or permanent implants. Main outcome measures were enophthalmos, diplopia, and ocular motility restriction 1.5 years after fracture repair. Implant-related complications were collected for analysis.
RESULTS: There were a total of 88 patients in our study. Bioresorbable implants were used in 48 patients (54.5%) while 40 patients had permanent implants (45.5%). The authors analyzed the implants used in various sizes of orbital fractures: small (<13.3 mm), medium (13.3-20 mm), and large (>20 mm). One and a half years after fracture repair, both groups had comparable clinical outcomes (n = 2 and n = 0 for diplopia for permanent and bioresorbable implant groups, respectively, n = 0 for enophthalmos for both groups and n = 1 for ocular motility limitation for both groups) overall and across all fracture sizes.
CONCLUSION: Bioresorbable implants degrade after fracture healing through hydrolysis and promote the gradual transfer of functional forces to healing bone during its disintegration. The clinical outcomes of diplopia, enophthalmos, and ocular motility restriction associated with the use of resorbable implants are comparable to that of permanent implants for all fracture sizes. Their study shows that bioresorbable and permanent implants are equally safe and effective for the treatment of patients with isolated orbital floor blowout fractures.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Systemic lupus erythematosus.Lancet 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app