We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
MULTICENTER STUDY
SURGICAL OUTCOMES AFTER INVERTED INTERNAL LIMITING MEMBRANE FLAP VERSUS CONVENTIONAL PEELING FOR VERY LARGE MACULAR HOLES.
Retina 2019 August
PURPOSE: To evaluate the anatomical and visual outcomes of inverted flap technique of peeling of internal limiting membrane (ILM) versus standard peeling of ILM for macular holes of basal diameter more than 800 μm.
METHODS: Patients with very large idiopathic macular holes more than 800 μm in basal diameter (ranging from 243 μm to 840 μm in minimum diameter) were retrospectively included in the study. In Group A, 18 eyes of 18 patients underwent ILM peeling using the inverted flap technique. In Group B, 18 eyes of 18 patients underwent conventional ILM peeling. The primary endpoint was the rate of hole closure at 6 months after surgery. The secondary outcome measure was the change in best-corrected visual acuity at 6 months after surgery.
RESULTS: There were no significant differences in ocular characteristics of the study groups at baseline except for the age distribution. Mean macular hole diameter was 1,162.8 ± 206.0 μm and 1,229.6 ± 228.1 μm in Group A and Group B, respectively. The hole closure rate was 88.9% (16/18) in Group A and 77.8% (14/18) in Group B (P = 0.66). The mean gain in best-corrected visual acuity was higher in Group A than in Group B (P = 0.12) at 6 months, but this was not statistically significant. There were no severe ocular adverse events in either group.
CONCLUSION: In this multicenter series, inverted ILM flap technique did not lead to significantly higher anatomical closure rates than conventional ILM peeling in large macular holes more than 800 μm in diameter.
METHODS: Patients with very large idiopathic macular holes more than 800 μm in basal diameter (ranging from 243 μm to 840 μm in minimum diameter) were retrospectively included in the study. In Group A, 18 eyes of 18 patients underwent ILM peeling using the inverted flap technique. In Group B, 18 eyes of 18 patients underwent conventional ILM peeling. The primary endpoint was the rate of hole closure at 6 months after surgery. The secondary outcome measure was the change in best-corrected visual acuity at 6 months after surgery.
RESULTS: There were no significant differences in ocular characteristics of the study groups at baseline except for the age distribution. Mean macular hole diameter was 1,162.8 ± 206.0 μm and 1,229.6 ± 228.1 μm in Group A and Group B, respectively. The hole closure rate was 88.9% (16/18) in Group A and 77.8% (14/18) in Group B (P = 0.66). The mean gain in best-corrected visual acuity was higher in Group A than in Group B (P = 0.12) at 6 months, but this was not statistically significant. There were no severe ocular adverse events in either group.
CONCLUSION: In this multicenter series, inverted ILM flap technique did not lead to significantly higher anatomical closure rates than conventional ILM peeling in large macular holes more than 800 μm in diameter.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app