We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
Comparison of transabdominal and transvaginal sonography in the diagnosis of placenta previa.
Journal of Clinical Ultrasound : JCU 2018 July
PURPOSE: To compare the accuracies of transabdominal sonography (TAS) and transvaginal sonography (TVS) in the diagnosis of placenta previa.
METHODS: A prospective, cross-sectional study was conducted at a university hospital. Both TAS and TVS were performed on 81 pregnant women with a suspicion of placenta previa in the third trimester. The final diagnosis was confirmed at delivery. The agreement between the two ultrasound methods and the parameters of each method were calculated.
RESULTS: Fifty-eight percent of the women had a placenta previa. The sensitivities of TAS and TVS were 86% (95% CI 78-94%) and 95% (95% CI 91-100%), respectively (p= 0.2). The specificity of both methods was 93% (95 CI 88-99%), and the overall accuracies of TAS and TVS were 89% (95% CI 82-96%) and 94% (95% CI 89-100%), respectively. When TAS was followed by TVS, 23% of the previous diagnoses were changed. The agreement between both methods was good (Kappa value = 0.7, 95%CI 0.55-0.86).
CONCLUSIONS: For the diagnosis of placenta previa, TAS showed a high sensitivity and specificity, which were comparable to those of TVS.
METHODS: A prospective, cross-sectional study was conducted at a university hospital. Both TAS and TVS were performed on 81 pregnant women with a suspicion of placenta previa in the third trimester. The final diagnosis was confirmed at delivery. The agreement between the two ultrasound methods and the parameters of each method were calculated.
RESULTS: Fifty-eight percent of the women had a placenta previa. The sensitivities of TAS and TVS were 86% (95% CI 78-94%) and 95% (95% CI 91-100%), respectively (p= 0.2). The specificity of both methods was 93% (95 CI 88-99%), and the overall accuracies of TAS and TVS were 89% (95% CI 82-96%) and 94% (95% CI 89-100%), respectively. When TAS was followed by TVS, 23% of the previous diagnoses were changed. The agreement between both methods was good (Kappa value = 0.7, 95%CI 0.55-0.86).
CONCLUSIONS: For the diagnosis of placenta previa, TAS showed a high sensitivity and specificity, which were comparable to those of TVS.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app