Scapholunate instability: improved detection with semi-automated kinematic CT analysis during stress maneuvers.
European Radiology 2018 October
OBJECTIVES: To evaluate the diagnostic performance of radioulnar deviation (RUD) and clenching fist (CF) maneuvers for the evaluation of scapholunate dissociation (SLD) using quantitative kinematic CT.
METHODS: Thirty-seven patients with suspected scapholunate instability were prospectively evaluated with kinematic CT. Two radiologists independently evaluated the SLD during RUD and CF maneuvers. Various dynamic parameters describing SLD were compared (maximal value, variation coefficient and range) in patients with and without scapholunate ligament ruptures confirmed by CT arthrography.
RESULTS: SLD in CF varied from 3.17 ± 0.38 to 3.24 ± 0.80 mm in controls and from 4.11 ± 0.77 and 4.01 ± 0.85 mm in patients with scapholunate ligament ruptures for reader 1 and 2 (p < 0.009). SLD in RUD varied from 3.35 ± 0.51 and 3.01 ± 0.78 mm in controls and from 4.51 ± 1.26 to 4.42 ± 1.75 mm in patients with scapholunate ligament ruptures for reader 1 and 2 (p varied from 0.001 to 0.002). The inter-observer variability was better for RUD (ICC = 0.85 versus 0.6 for RUD and CF respectively).
CONCLUSION: Analysis of SLD using kinematic CT has shown significant measurement differences between the groups with or without scapholunate instability with good diagnostic performance.
KEY POINTS: • Kinematic CT can quantitatively assess scapholunate dissociation. • SLD analysis on kinematic CT has excellent reproducibility with radioulnar deviation maneuver. • Scapholunate dissociation was significantly different in patients with and without instability. • Diagnostic performance for scapholunate instability identification was better with radioulnar deviation.
METHODS: Thirty-seven patients with suspected scapholunate instability were prospectively evaluated with kinematic CT. Two radiologists independently evaluated the SLD during RUD and CF maneuvers. Various dynamic parameters describing SLD were compared (maximal value, variation coefficient and range) in patients with and without scapholunate ligament ruptures confirmed by CT arthrography.
RESULTS: SLD in CF varied from 3.17 ± 0.38 to 3.24 ± 0.80 mm in controls and from 4.11 ± 0.77 and 4.01 ± 0.85 mm in patients with scapholunate ligament ruptures for reader 1 and 2 (p < 0.009). SLD in RUD varied from 3.35 ± 0.51 and 3.01 ± 0.78 mm in controls and from 4.51 ± 1.26 to 4.42 ± 1.75 mm in patients with scapholunate ligament ruptures for reader 1 and 2 (p varied from 0.001 to 0.002). The inter-observer variability was better for RUD (ICC = 0.85 versus 0.6 for RUD and CF respectively).
CONCLUSION: Analysis of SLD using kinematic CT has shown significant measurement differences between the groups with or without scapholunate instability with good diagnostic performance.
KEY POINTS: • Kinematic CT can quantitatively assess scapholunate dissociation. • SLD analysis on kinematic CT has excellent reproducibility with radioulnar deviation maneuver. • Scapholunate dissociation was significantly different in patients with and without instability. • Diagnostic performance for scapholunate instability identification was better with radioulnar deviation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app