Intra- and Interobserver Reliability of Size Measurement of Morton Neuromas on Sonography.
Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine 2019 September
OBJECTIVES: Sonography is often used for analysis of Morton neuromas, but the measurement reliability is unknown. The aim of this study was to determine the intra- and interobserver reliability and precision of sonographic measurement of Morton neuromas.
METHODS: Three observers with different levels of sonography experience (observer A, expert; observer B, intermediate; observer C, beginner) performed repeated measurements of the size of Morton's neuroma in 20 patients. Intraclass correlation coefficient and limit of agreement were used to evaluate reliability and measurement precision.
RESULTS: The intraclass correlation coefficient for intraobserver reliability was 0.80, 0.71, and 0.43 (limit of agreement, 20%, 18%, and 47%) in observers A, B, and C, respectively. The intraclass correlation coefficient for interobserver reliability was 0.72, 0.38, and 0.38 (limit of agreement, 25%, 36%, and 35%) between observers A/B, A/C, and B/C, respectively.
CONCLUSIONS: The intra- and interobserver reliability values for sonographic measurement of Morton neuroma size were dependent on observer experience. Experienced observers had higher reliability, while observers who were less familiar with sonography showed moderate to low reliability.
METHODS: Three observers with different levels of sonography experience (observer A, expert; observer B, intermediate; observer C, beginner) performed repeated measurements of the size of Morton's neuroma in 20 patients. Intraclass correlation coefficient and limit of agreement were used to evaluate reliability and measurement precision.
RESULTS: The intraclass correlation coefficient for intraobserver reliability was 0.80, 0.71, and 0.43 (limit of agreement, 20%, 18%, and 47%) in observers A, B, and C, respectively. The intraclass correlation coefficient for interobserver reliability was 0.72, 0.38, and 0.38 (limit of agreement, 25%, 36%, and 35%) between observers A/B, A/C, and B/C, respectively.
CONCLUSIONS: The intra- and interobserver reliability values for sonographic measurement of Morton neuroma size were dependent on observer experience. Experienced observers had higher reliability, while observers who were less familiar with sonography showed moderate to low reliability.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app