We have located links that may give you full text access.
Does Mesh Weight Affect Time to Failure After Robotic-Assisted Laparoscopic Sacrocolpopexy?
Female Pelvic Medicine & Reconstructive Surgery 2018 October 13
OBJECTIVE: The objective of this study was to compare time to anatomic failure after robotic sacrocolpopexy with use of ultralightweight versus heavier weight mesh types.
METHODS: We performed a retrospective cohort study of women who underwent robotic sacrocolpopexy, from January 2012 to September 2016. We compared (1) sacrocolpopexy with ultralightweight mesh (≤20 g/m) versus (2) sacrocolpopexy with heavier weight mesh (≤35 g/m). Our primary outcome was time to anatomic failure, defined as recurrent prolapse beyond the hymen, or retreatment for prolapse with surgery or pessary. Secondary outcomes were compartment of failure and mesh exposure. Cox proportional hazards modeling was used to estimate the hazard of failure based on mesh type.
RESULTS: Of 461 patients, 248 (53.8%) underwent sacrocolpopexy with ultralightweight mesh and 213 (46.2%) with heavier weight mesh. Failures occurred in 37 women, with 21 in the ultralightweight mesh group and 16 in the heavier weight mesh group. Time to failure was statistically significant between groups (P = 0.03). Ultralightweight mesh had twice the hazard of failure within 3 years compared with heavier weight mesh (hazard ratio, 2.15; 95% confidence interval, 1.10-4.21; P = 0.03). Among failures, use of ultralightweight mesh was associated with almost 5 times the hazard of anterior compartment failure (hazard ratio, 4.46; 95% confidence interval, 1.39-14.27; P = 0.01). There was no difference in time to posterior failure. Of 17 mesh exposures, there were fewer in the ultralightweight mesh group, although this group was followed for less time (1.6% ultralightweight vs 6.0% heavier weight, P = 0.01).
CONCLUSIONS: Women receiving ultralightweight mesh are more likely to experience earlier anatomic failure in the anterior compartment.
METHODS: We performed a retrospective cohort study of women who underwent robotic sacrocolpopexy, from January 2012 to September 2016. We compared (1) sacrocolpopexy with ultralightweight mesh (≤20 g/m) versus (2) sacrocolpopexy with heavier weight mesh (≤35 g/m). Our primary outcome was time to anatomic failure, defined as recurrent prolapse beyond the hymen, or retreatment for prolapse with surgery or pessary. Secondary outcomes were compartment of failure and mesh exposure. Cox proportional hazards modeling was used to estimate the hazard of failure based on mesh type.
RESULTS: Of 461 patients, 248 (53.8%) underwent sacrocolpopexy with ultralightweight mesh and 213 (46.2%) with heavier weight mesh. Failures occurred in 37 women, with 21 in the ultralightweight mesh group and 16 in the heavier weight mesh group. Time to failure was statistically significant between groups (P = 0.03). Ultralightweight mesh had twice the hazard of failure within 3 years compared with heavier weight mesh (hazard ratio, 2.15; 95% confidence interval, 1.10-4.21; P = 0.03). Among failures, use of ultralightweight mesh was associated with almost 5 times the hazard of anterior compartment failure (hazard ratio, 4.46; 95% confidence interval, 1.39-14.27; P = 0.01). There was no difference in time to posterior failure. Of 17 mesh exposures, there were fewer in the ultralightweight mesh group, although this group was followed for less time (1.6% ultralightweight vs 6.0% heavier weight, P = 0.01).
CONCLUSIONS: Women receiving ultralightweight mesh are more likely to experience earlier anatomic failure in the anterior compartment.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app