We have located links that may give you full text access.
Case Reports
Journal Article
Review
Misplacement of Tunneled Hemodialysis Catheter into Azygos Vein: Left or Right Jugular Insertion Has Similar Susceptibility.
Blood Purification 2019
BACKGROUND: Central venous catheter (CVC) is commonly used to provide access for hemodialysis (HD) when arteriovenous access is not available. The misplacement of CVC into azygos vein (AV) is a rare but a potential serious complication. Previous reports communicated the opinion that left-sided catheterization predisposed to AV misplacement, but these reports concentrated on peripherally inserted CVCs, placed for indications rather than HD. Unintended AV misplacement of HD catheters (HDCs) has not been well studied. We seek to investigate factors associated with inadvertent AV miscannulation during HDC placement.
METHODS: We are to present a case of unintentional misplacement of a tunneled HD catheter (tHDC) into the azygos arch from right internal jugular vein (RIJV) despite real-time fluoroscopy guidance. Additionally, we have undertaken a systematic literature search in Pubmed to study the anatomical and other factors related to unintended AV misposition in HD setting.
RESULTS: From 2005 to August 31, 2018, a total of 11 articles containing 16 cases of misplacement of HDCs into AV were identified. Of the 17 cases of unintentional AV misposition including ours, the majority of the misguided HDCs (94.1%, 16/17) were tHDCs and only 1 case was related to a temporary (non-tunneled) catheter. Most catheter misplacements (88.2%, 15/17) were performed without real-time radiological guidance. The reported incidence of inadvertent AV cannulation from different institutions varied between 0.6% and 3.8%. Among the 16 misplaced tHDCs, the rates of AV misposition that arose from RIJV and left internal jugular vein (LIJV) insertion are even at 50%.
CONCLUSIONS: Based upon anatomical and case studies, we have found that AV may join posterior aspect of superior vena cava at different directions and levels. Hence, this might explain why AV misplacement might occur whether an HDC is inserted from the LIJV or RIJV approach. By raising the awareness of this potential complication and how we may minimize it, we hope to reduce the future complication of AV misposition.
METHODS: We are to present a case of unintentional misplacement of a tunneled HD catheter (tHDC) into the azygos arch from right internal jugular vein (RIJV) despite real-time fluoroscopy guidance. Additionally, we have undertaken a systematic literature search in Pubmed to study the anatomical and other factors related to unintended AV misposition in HD setting.
RESULTS: From 2005 to August 31, 2018, a total of 11 articles containing 16 cases of misplacement of HDCs into AV were identified. Of the 17 cases of unintentional AV misposition including ours, the majority of the misguided HDCs (94.1%, 16/17) were tHDCs and only 1 case was related to a temporary (non-tunneled) catheter. Most catheter misplacements (88.2%, 15/17) were performed without real-time radiological guidance. The reported incidence of inadvertent AV cannulation from different institutions varied between 0.6% and 3.8%. Among the 16 misplaced tHDCs, the rates of AV misposition that arose from RIJV and left internal jugular vein (LIJV) insertion are even at 50%.
CONCLUSIONS: Based upon anatomical and case studies, we have found that AV may join posterior aspect of superior vena cava at different directions and levels. Hence, this might explain why AV misplacement might occur whether an HDC is inserted from the LIJV or RIJV approach. By raising the awareness of this potential complication and how we may minimize it, we hope to reduce the future complication of AV misposition.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app