Add like
Add dislike
Add to saved papers

Diagnostic Performance of 4D CT and Sestamibi SPECT/CT in Localizing Parathyroid Adenomas in Primary Hyperparathyroidism.

Radiology 2019 May
Background There currently is no consensus on the optimal localization procedure and imaging protocol for parathyroid adenoma. Parathyroid four-dimensional (4D) CT has emerged as a promising method for preoperative localization. Purpose To evaluate the diagnostic performance of parathyroid 4D CT and technetium 99m-sestamibi (hereafter, referred to as sestamibi) SPECT/CT in preoperative localization in patients with primary hyperparathyroidism. Materials and Methods This was a single-institution retrospective study of patients with primary hyperparathyroidism who underwent a combined imaging protocol of sestamibi SPECT/CT and 4D CT (noncontrast, contrast agent-enhanced, arterial, and delayed venous phases) acquired in a single setting from February 2013 to May 2016, with subsequent parathyroidectomy within 6 months. Reference standard for correct localization was on the basis of location denoted on operative reports, with pathologic confirmation of parathyroid adenoma or hyperplasia. By using a four-quadrant analysis, sensitivity, specificity, and area under the curve (AUC) for localization of the hyperfunctioning parathyroid gland or glands at sestamibi SPECT/CT and 4D CT were compared, per modality and in combination. Results Four hundred patients (319 women, 81 men; mean age, 61 years ± 14 [standard deviation]) were evaluated. Similar diagnostic performance was found in both combined 4D CT with sestamibi SPECT/CT and 4D CT alone (area under the curve [AUC], 0.88 [95% CI: 0.86, 0.90] and 0.87 [95% CI: 0.85, 0.90], respectively; P = .82). Both modalities outperformed sestamibi SPECT/CT (AUC, 0.78; 95% CI: 0.76, 0.81; P < .001). Four-dimensional CT showed higher sensitivity than did sestamibi SPECT/CT (sensitivity, 79.3% [414 of 522] vs 58.0% [303 of 522], respectively; P < .001). In a subset analysis, 4D CT had higher sensitivity than sestamibi SPECT/CT in patients with single-gland disease (sensitivity, 92.5% [297 of 321] vs 75.1% [241 of 321], respectively; P < .001) and with multigland disease (sensitivity, 58.2% [117 of 201] vs 30.8% [62 of 201], respectively; P < .001). Conclusion Four-dimensional CT provided superior preoperative localization compared with sestamibi SPECT/CT in patients with single and multigland disease. The combination of the two modalities did not improve diagnostic performance compared with four-dimensional CT alone. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Sinha and Oates in this issue.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app