Add like
Add dislike
Add to saved papers

Generalized linear model (GLM) analysis: Multivariables of microcalcification specimens obtained via X-ray guided by stereotactic wire localization biopsy.

OBJECTIVE: To retrospectively explore correlation of the resected specimen volume of breast microcalcification lesions and endogenous and exogenous factors of stereotactic needle localization biopsy (SNLB).

MATERIALS AND METHODS: Totally 214 patients underwent SNLB for non-palpable breast lesion with microcalcification lesions. Of 211 patients, 198 patients underwent single needle localization and 13 patients underwent multi-needle localization (26 lesions). Lesion sizes, distribution characteristics, lesion localization accuracy and resected specimen volumes were recorded and analyzed using a generalized linear model (GLM).

RESULTS: The average lesion diameter is 2.63±1.73 cm. The localization accuracy of 187 lesions were moderate, 26 were too deep and 11 were too superficial. The mean resected specimen volume (V) was 17.51±5.14 cm3. One-way ANOVA analysis showed that 3 factors, including lesion sizes, distribution characteristics and the localization accuracy were associated with resected specimen volume (F = 67.56-112.78, P <  0.001). GLM revealed that lesion sizes, single clustered distribution and accurate localization were significant factors for resected specimen volume (F = -4.82-11.36, P <  0.05). The ratio (%) of the resected specimen volume to the involved breast volume (V0) was defined as the degree of breast defect. The mean breast defect of 125 benign patients (V/V0) was 27.5% ranging from 10.1% to 42.3% .

CONCLUSION: Average lesion diameter and localization accuracy are highly significant variables for the resected specimen volume. Localization accuracy as a subjective controllable variable is one of the important factors that determine the volume of lesion resection. Single clustered distribution was more susceptible localization accuracy than other characteristic distributions. Improving localization accuracy can reduce resected specimen volume, which can reduce breast defect to a certain extent.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app