We have located links that may give you full text access.
Journal Article
Research Support, Non-U.S. Gov't
Smaller-Diameter Covered Transjugular Intrahepatic Portosystemic Shunt Stents Are Associated With Increased Survival.
Clinical Gastroenterology and Hepatology 2019 December
BACKGROUND & AIMS: We studied the effects of diameter of covered, self-expandable, nitinol stents on survival times of patients with a transjugular intrahepatic portosystemic shunt (TIPS).
METHODS: We collected data from 185 patients (median age, 55 y; 30% female) who received a covered nitinol stent, from February 2006 through September 2010, using the online multicenter German TIPS registry. TIPS were given to 107 patients for refractory ascites and to 78 patients for variceal bleeding. Patients at risk of hepatic encephalopathy (owing to advanced age, prior episodes) or liver failure (bilirubin level, >3 mg/dL), and bleeding patients receiving variceal embolization at TIPS, received 8-mm stents (n = 53). The remaining patients received 10-mm stents (n = 132). Eighty-one of the 10-mm stents were underdilated using 8-mm dilation balloons. Clinical and biochemical data were collected after TIPS placement at 1 month, 3 months, 6 months, 9 months, 1 year, and thereafter every 3 to 6 months. Groups were compared using propensity score analysis.
RESULTS: Patients who received 8-mm stents survived significantly longer (34 ± 26 mo) than patients who received 10-mm stents (18 ± 19 mo), regardless of whether they were fully dilated or underdilated. When we compared 10-mm stents with or without underdilation, we found that a significantly higher proportion of patients who received underdilated stents survived for 1 month after TIPS placement (95% vs 84%; P = .03), but not for 3 months (P = .10). In multivariate analysis, 1-year mortality correlated with full dilation of the stent to 10 mm (hazard ratio [HR], 2.0; 95% CI, 1.1-3.5) and with serum creatinine concentration at baseline (HR, 1.5; 95% CI, 1.0-1.7). Five-year mortality was associated with use of the 10-mm stents (HR, 1.8; 95% CI, 1.4-2.7) and baseline concentration of creatinine (HR, 1.3; 95% CI, 1.1-1.6).
CONCLUSIONS: A smaller stent (nominal diameter of 8 mm, but not underdilation of a 10-mm stent) is associated with a prolonged survival compared with 10-mm stents, independent of liver-specific prognostic criteria.
METHODS: We collected data from 185 patients (median age, 55 y; 30% female) who received a covered nitinol stent, from February 2006 through September 2010, using the online multicenter German TIPS registry. TIPS were given to 107 patients for refractory ascites and to 78 patients for variceal bleeding. Patients at risk of hepatic encephalopathy (owing to advanced age, prior episodes) or liver failure (bilirubin level, >3 mg/dL), and bleeding patients receiving variceal embolization at TIPS, received 8-mm stents (n = 53). The remaining patients received 10-mm stents (n = 132). Eighty-one of the 10-mm stents were underdilated using 8-mm dilation balloons. Clinical and biochemical data were collected after TIPS placement at 1 month, 3 months, 6 months, 9 months, 1 year, and thereafter every 3 to 6 months. Groups were compared using propensity score analysis.
RESULTS: Patients who received 8-mm stents survived significantly longer (34 ± 26 mo) than patients who received 10-mm stents (18 ± 19 mo), regardless of whether they were fully dilated or underdilated. When we compared 10-mm stents with or without underdilation, we found that a significantly higher proportion of patients who received underdilated stents survived for 1 month after TIPS placement (95% vs 84%; P = .03), but not for 3 months (P = .10). In multivariate analysis, 1-year mortality correlated with full dilation of the stent to 10 mm (hazard ratio [HR], 2.0; 95% CI, 1.1-3.5) and with serum creatinine concentration at baseline (HR, 1.5; 95% CI, 1.0-1.7). Five-year mortality was associated with use of the 10-mm stents (HR, 1.8; 95% CI, 1.4-2.7) and baseline concentration of creatinine (HR, 1.3; 95% CI, 1.1-1.6).
CONCLUSIONS: A smaller stent (nominal diameter of 8 mm, but not underdilation of a 10-mm stent) is associated with a prolonged survival compared with 10-mm stents, independent of liver-specific prognostic criteria.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app