Endoscopic full-thickness transoral outlet reduction with semicircumferential endoscopic submucosal dissection.
Endoscopy 2019 July
BACKGROUND: Endoscopic full-thickness transoral outlet reduction (efTOR) is a therapeutic option to reduce a dilated gastrojejunal anastomosis (GJA) after Roux-en-Y gastric bypass (RYGB). Mucosal ablation with argon plasma coagulation (APC) is usually performed to achieve tissue adaptation. However, rupture of sutures before scarring can lead to recurrent dilatation of the GJA. Here, we describe efTOR with a semicircumferential endoscopic submucosal dissection (ESD-efTOR) as an alternative to APC-efTOR.
METHODS: We enrolled 41 patients with comparable baseline characteristics (APC-efTOR 26; ESD-efTOR 15). The main objectives were reduction in the GJA diameter and in ruptured sutures. Technical success, complications, total weight loss (TWL), and percentage of total and excess weight loss (%TWL and %EWL) at 3 and 12 months, were assessed.
RESULTS: ESD-efTOR resulted in significantly fewer ruptured sutures (20 % vs. 69 %; P = 0.004) and a greater reduction in the GJA (major 20 % vs. 0 %; minor 54 % vs. 37 %; no reduction 13 % vs. 58 %; P = 0.02) after 3 months. Technical efficacy, examination time, and rate of complications were comparable.
CONCLUSIONS: ESD-efTOR resulted in a significantly greater reduction in the GJA diameter and a lower risk of ruptured sutures compared with APC-efTOR.
METHODS: We enrolled 41 patients with comparable baseline characteristics (APC-efTOR 26; ESD-efTOR 15). The main objectives were reduction in the GJA diameter and in ruptured sutures. Technical success, complications, total weight loss (TWL), and percentage of total and excess weight loss (%TWL and %EWL) at 3 and 12 months, were assessed.
RESULTS: ESD-efTOR resulted in significantly fewer ruptured sutures (20 % vs. 69 %; P = 0.004) and a greater reduction in the GJA (major 20 % vs. 0 %; minor 54 % vs. 37 %; no reduction 13 % vs. 58 %; P = 0.02) after 3 months. Technical efficacy, examination time, and rate of complications were comparable.
CONCLUSIONS: ESD-efTOR resulted in a significantly greater reduction in the GJA diameter and a lower risk of ruptured sutures compared with APC-efTOR.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app