Exploring the Incidence, Implications, and Relevance of Metal Allergy to Orthopaedic Surgeons.

INTRODUCTION: Allergic reactions to metal implants are increasingly recognized, but its relevance to the orthopaedic surgeon remains unclear. We evaluate the prevalence of metal allergies in a subset of the population and review the significance through a survey of the current literature.

METHODS: Preoperative and postoperative patients referred for metal allergy testing were divided into two groups; those with a history of dermatitis and those without. Patients with a history of dermatitis were offered skin patch testing that included the North American Contact Dermatitis core allergen panels in addition to our metal screening series. Patients without dermatitis were tested to the more limited patch testing metal screening series. Some patients with dermatitis opted for the more limited screening, whereas some patients without dermatitis underwent more extensive testing at their request or at the request of the referring clinician. Patch tests were evaluated at 2 and 4 days after placement.

RESULTS: Hundred patients were referred for metal allergy testing, 46 of whom were for reasons related to planned orthopaedic surgery. Of those tested, 60 patients had a history of dermatitis and 40 did not. Some patients were nonreactive to all tested allergens, whereas others demonstrated one or more positive skin patch test reactions. The number of positive reactions to each metal in patients with a history of dermatitis was the following: nickel 19, amalgam 10, palladium 10, copper 8, cobalt 5, mercury 5, tin 2, gold 1, titanium 1, and vanadium 1. The number of positive reactions to metals in patients without a history of dermatitis was the following: nickel 4, amalgam 5, palladium 4, mercury 4, cobalt 4, tin 2, copper 2, gold 1, vanadium 1, and molybdenum 1.

DISCUSSION: Metal allergy was common in the individuals referred for testing, with reactions to nickel and amalgam being the most commonly encountered. Some individuals experience more notable allergic reactions to implanted devices than others. Localized and generalized skin reactions have been reported, along with implant failure and loosening. Surgeons should be aware of the incidence of metal allergies and the potential consequences.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app