Accuracy of the Ultrasound Estimate of the Amniotic Fluid Volume (Amniotic Fluid Index and Single Deepest Pocket) to Identify Actual Low, Normal, and High Amniotic Fluid Volumes as Determined by Quantile Regression.
Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine 2020 Februrary
OBJECTIVES: To identify abnormal amniotic fluid volumes (AFVs), normal volumes must be determined. Multiple statistical methods are used to define normal amniotic fluid curves; however, quantile regression (QR) is gaining favor. We reanalyzed ultrasound estimates in identifying oligohydramnios, normal fluid, and polyhydramnios using normal volumes calculated by QR.
METHODS: Data from 506 dye-determined or directly measured AFVs along with ultrasound estimates were analyzed. Each was classified as low, normal, or high for both the single deepest pocket (SDP) and amniotic fluid index (AFI). A weighted κ statistic was used to assess the level of agreement between the AFI and SDP compared to actual AFVs by QR.
RESULTS: The overall level of agreement for the AFI was fair (κ = 0.26), and that for the SDP was slight (κ = 0.19). Although not statistically significant (P = .792), the positive predictive value to classify a low volume using the AFI was lower compared to the SDP (35% vs 43%). The positive predictive value for a high volume was higher using the AFI compared to the SDP (55% versus 31%) but not statistically significant. The missed-call rate for high-volume identification by the SDP versus AFI was statistically significant (odds ratio, 5.5; 95% confidence interval, 2.04-14.97). The missed-call rate for low-volume identification by the AFI versus SDP was not statistically significant (odds ratio, 3.3; 95% confidence interval, 0.96-11.53).
CONCLUSIONS: Both the AFI and SDP identify actual normal AFVs by QR, with sensitivity higher than 90%. The SDP is superior for identification of oligohydramnios, and the AFI superior for identification of polyhydramnios.
METHODS: Data from 506 dye-determined or directly measured AFVs along with ultrasound estimates were analyzed. Each was classified as low, normal, or high for both the single deepest pocket (SDP) and amniotic fluid index (AFI). A weighted κ statistic was used to assess the level of agreement between the AFI and SDP compared to actual AFVs by QR.
RESULTS: The overall level of agreement for the AFI was fair (κ = 0.26), and that for the SDP was slight (κ = 0.19). Although not statistically significant (P = .792), the positive predictive value to classify a low volume using the AFI was lower compared to the SDP (35% vs 43%). The positive predictive value for a high volume was higher using the AFI compared to the SDP (55% versus 31%) but not statistically significant. The missed-call rate for high-volume identification by the SDP versus AFI was statistically significant (odds ratio, 5.5; 95% confidence interval, 2.04-14.97). The missed-call rate for low-volume identification by the AFI versus SDP was not statistically significant (odds ratio, 3.3; 95% confidence interval, 0.96-11.53).
CONCLUSIONS: Both the AFI and SDP identify actual normal AFVs by QR, with sensitivity higher than 90%. The SDP is superior for identification of oligohydramnios, and the AFI superior for identification of polyhydramnios.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app