CT-based liver surface nodularity for the detection of clinically significant portal hypertension: defining measurement quality criteria.

Abdominal Radiology 2020 September
PURPOSE: To establish measurement quality criteria for the noninvasive assessment of clinically significant portal hypertension (CSPH) in patients with cirrhosis using CT-based liver surface nodularity (LSN) measurements.

METHODS: Seventy-four consecutive patients with cirrhosis (mean 62 ± 13 years), including 30 with CSPH (41%), underwent CT and hepatic venous pressure gradient measurements. Three independent readers performed 15 LSN measurements/patient using dedicated software. LSN was computed based on the median and means of one to 15 measurements. Accuracy for diagnosing CSPH was assessed using receiver operating characteristic (ROC) curve analysis. Variability was assessed by the intra-class correlation coefficient (ICC) and the Bland-Altman plot (BA). Quality criteria were identified to maximize the accuracy of LSN and minimize variability.

RESULTS: The area under the (AU) ROCs of mean and median LSN measurements based on one to 15 measurements ranged from 0.79 ± 0.05 to 0.91 ± 0.04 and 0.86 ± 0.04 to 0.91 ± 0.03, respectively, with no difference on pair-wise comparisons (all p > 0.05). AUROCs of LSN increased from one to eight and leveled off between eight and 15 measurements. Inter- and intra-reader variability decreased from one to 15 measurements, with only slight improvement after more than eight measurements. Intra- and inter-observer agreements were excellent with eight measurements (ICC = 0.90 [95%CI 0.84-0.94], and ICC = 0.93 [95%CI 0.89-0.95], respectively), and variability for intra-observer and inter-observer agreement was low (BA bias 4.2% (95% limits of agreement [LoA] [- 15.3; + 23.7%]) and 4.8% LoA [ - 17.5; + 27.1%], respectively).

CONCLUSIONS: CT-based LSN measurement is highly reproducible and accurate. We suggest using at least 8 valid measurements to determine the mean LSN value for the detection of CSPH.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app