Where should the pins be placed to decrease the failure rate after fixation of a Mayo IIA olecranon fracture? A biomechanical analysis.
Injury 2020 May 20
BACKGROUND: Clinically, treatment of Mayo IIA olecranon fractures (MIOF) using pins is associated with a high rate of failure. The purpose of our study was to compare the biomechanical stability and strength of four different fracture fixation configurations and to recommend the best method for the clinical treatment of MIOFs.
METHODS: Twenty synthetic ulnar models were created and equally divided into 4 different fracture fixation groups: a double cortical configuration using Kirschner (K) wires; a double cortical configuration using transcortical pins; an intramedullary pin system; and an intramedullary pin system with a 3-mm distance between the eyelet and the proximal end of the olecranon (loose fixation). The stiffness and strength of all specimens were tested under a loading rate of 2 mm/min. Between-group differences were evaluated using an independent t-test, with significance set at P < 0.05.
RESULTS: Stiffness and strength were significantly better for the K-wire than intramedullary group: stiffness, 63.467±14.063 N/mm and 36.243±5.625 N/mm, respectively (P=0.009); and strength, 624.293±148.728 N and 406.486±74.109 N, respectively (P=0.019). There was no difference in stiffness (P=0.370) or strength (P=0.929) between the use of transcortical pins and K-wires. Moreover, a 3-mm prominence of the pin at the olecranon did not have a negative effect on either stiffness (P=0.494) or strength (P=0.391).
CONCLUSIONS: Our biomechanical analysis indicated that using a double cortical pin configuration provided the best stability and strength and, thus, may lower the risk of fracture fixation failure. The use of either K-wires or pins in the double cortical configuration did not influence fixation stability. A loose double cortical configuration might decrease fracture stability, although there differences were not significant.
METHODS: Twenty synthetic ulnar models were created and equally divided into 4 different fracture fixation groups: a double cortical configuration using Kirschner (K) wires; a double cortical configuration using transcortical pins; an intramedullary pin system; and an intramedullary pin system with a 3-mm distance between the eyelet and the proximal end of the olecranon (loose fixation). The stiffness and strength of all specimens were tested under a loading rate of 2 mm/min. Between-group differences were evaluated using an independent t-test, with significance set at P < 0.05.
RESULTS: Stiffness and strength were significantly better for the K-wire than intramedullary group: stiffness, 63.467±14.063 N/mm and 36.243±5.625 N/mm, respectively (P=0.009); and strength, 624.293±148.728 N and 406.486±74.109 N, respectively (P=0.019). There was no difference in stiffness (P=0.370) or strength (P=0.929) between the use of transcortical pins and K-wires. Moreover, a 3-mm prominence of the pin at the olecranon did not have a negative effect on either stiffness (P=0.494) or strength (P=0.391).
CONCLUSIONS: Our biomechanical analysis indicated that using a double cortical pin configuration provided the best stability and strength and, thus, may lower the risk of fracture fixation failure. The use of either K-wires or pins in the double cortical configuration did not influence fixation stability. A loose double cortical configuration might decrease fracture stability, although there differences were not significant.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Anti-Arrhythmic Effects of Heart Failure Guideline-Directed Medical Therapy and Their Role in the Prevention of Sudden Cardiac Death: From Beta-Blockers to Sodium-Glucose Cotransporter 2 Inhibitors and Beyond.Journal of Clinical Medicine 2024 Februrary 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app