Percutaneous-perventricular device closure of ventricular septal defect: mid-term follow-up.
BMC Surgery 2020 September 19
BACKGROUND: This report presents updated data and mid-term follow-up information to a former study introducing the novel technique of percutaneous-perventricular device closure of doubly committed subarterial ventricular septal defect.
METHODS: Thirty-eight patients were added to the former series. There were 54 patients in total who had isolated doubly committed subarterial ventricular septal defects and underwent percutaneous-perventricular device closure. Closure outcomes and possible complications were measured in the hospital and during the 2.5-year follow-up.
RESULTS: Surgery was successful in 53 patients (98.1%). There was no death, residual shunt, new valve regurgitation or arrhythmia either perioperatively or during the entire follow-up period. Only one patient developed pericardial effusion and tamponade in the former series. The mean hospital stay was 3.2 ± 0.6 days (range, 3.0 to 6.0 days), and only one unsuccessful case needed blood transfusion (1.9%).
CONCLUSIONS: The percutaneous-perventricular device closure of isolated doubly committed subarterial ventricular septal defects appeared to be safe. Close monitoring for bleeding is essential postoperatively, especially in younger patients. This technique is generally safe with acceptable mid-term follow-up.
METHODS: Thirty-eight patients were added to the former series. There were 54 patients in total who had isolated doubly committed subarterial ventricular septal defects and underwent percutaneous-perventricular device closure. Closure outcomes and possible complications were measured in the hospital and during the 2.5-year follow-up.
RESULTS: Surgery was successful in 53 patients (98.1%). There was no death, residual shunt, new valve regurgitation or arrhythmia either perioperatively or during the entire follow-up period. Only one patient developed pericardial effusion and tamponade in the former series. The mean hospital stay was 3.2 ± 0.6 days (range, 3.0 to 6.0 days), and only one unsuccessful case needed blood transfusion (1.9%).
CONCLUSIONS: The percutaneous-perventricular device closure of isolated doubly committed subarterial ventricular septal defects appeared to be safe. Close monitoring for bleeding is essential postoperatively, especially in younger patients. This technique is generally safe with acceptable mid-term follow-up.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app