We have located links that may give you full text access.
Autologous Retinal Transplantation for Primary and Refractory Macular Holes and Macular Hole Retinal Detachments: The Global Consortium.
Ophthalmology 2021 May
PURPOSE: To report the anatomic and functional outcomes of autologous retinal transplantation (ART).
DESIGN: Multicenter, retrospective, interventional, consecutive case series.
PARTICIPANTS: One hundred thirty eyes of 130 patients undergoing ART for the repair of primary and refractory macular holes (MHs), as well as combined MH-rhegmatogenous retinal detachment (MH-RRD), between January 2017 and December 2019.
METHODS: All patients underwent pars plana vitrectomy and ART, with surgeon modification of intraoperative variables. A large array of preoperative, intraoperative, and postoperative data was collected. Two masked reviewers graded OCT images. Multivariate statistical analysis and subgroup analysis were performed.
MAIN OUTCOME MEASURES: Macular hole closure rate, visual acuity (VA), external limiting membrane and ellipsoid zone (EZ) band integrity, and alignment of neurosensory layers (ANL) on OCT.
RESULTS: One hundred thirty ART surgeries were performed by 33 vitreoretinal surgeons worldwide. Patient demographics were: mean age of 63 ± 6.3 years, 58% female, 41% White, 23% Black, 19% Asian, and 17% Latino. Preoperative VA was 1.37 ± 0.12 logarithm of the minimum angle of resolution (logMAR; Snellen equivalent, approximately 20/500), which improved significantly to 1.05 ± 0.09 logMAR (Snellen equivalent, approximately 20/225; P < 0.001) after surgery (mean follow-up, 8.6 ± 0.8 months). Autologous retinal transplantation was performed for primary MH repair in 27% of patients (n = 35), for refractory MH in 58% of patients (n = 76; mean number of previous surgeries, 1.6 ± 0.2), and for MH-RRD in 15% of patients (n = 19). Mean maximum MH diameter was 1470 ± 160 μm, mean minimum diameter was 840 ± 94 μm, and mean axial length was 24.6 ± 3.2 mm. Overall, 89% of MHs closed (78.5% complete; 10% small eccentric defect), with a 95% closure rate in MH-RRD (68.4% complete; 26.3% small eccentric defect). Visual acuity improved by at least 3 lines in 43% of eyes and by at least 5 lines in 29% of eyes. Reconstitution of the EZ (P = 0.02) and ANL (P = 0.01) on OCT were associated with better final VA. Five cases of ART graft dislocation (3.8%), 5 cases of postoperative retinal detachment (3.8%), and 1 case of endophthalmitis (0.77%) occurred.
CONCLUSIONS: In this global experience, patients undergoing ART for large primary and refractory MHs and MH-RRDs achieved good anatomic and functional outcomes, with low complication rates despite complex surgical pathologic features.
DESIGN: Multicenter, retrospective, interventional, consecutive case series.
PARTICIPANTS: One hundred thirty eyes of 130 patients undergoing ART for the repair of primary and refractory macular holes (MHs), as well as combined MH-rhegmatogenous retinal detachment (MH-RRD), between January 2017 and December 2019.
METHODS: All patients underwent pars plana vitrectomy and ART, with surgeon modification of intraoperative variables. A large array of preoperative, intraoperative, and postoperative data was collected. Two masked reviewers graded OCT images. Multivariate statistical analysis and subgroup analysis were performed.
MAIN OUTCOME MEASURES: Macular hole closure rate, visual acuity (VA), external limiting membrane and ellipsoid zone (EZ) band integrity, and alignment of neurosensory layers (ANL) on OCT.
RESULTS: One hundred thirty ART surgeries were performed by 33 vitreoretinal surgeons worldwide. Patient demographics were: mean age of 63 ± 6.3 years, 58% female, 41% White, 23% Black, 19% Asian, and 17% Latino. Preoperative VA was 1.37 ± 0.12 logarithm of the minimum angle of resolution (logMAR; Snellen equivalent, approximately 20/500), which improved significantly to 1.05 ± 0.09 logMAR (Snellen equivalent, approximately 20/225; P < 0.001) after surgery (mean follow-up, 8.6 ± 0.8 months). Autologous retinal transplantation was performed for primary MH repair in 27% of patients (n = 35), for refractory MH in 58% of patients (n = 76; mean number of previous surgeries, 1.6 ± 0.2), and for MH-RRD in 15% of patients (n = 19). Mean maximum MH diameter was 1470 ± 160 μm, mean minimum diameter was 840 ± 94 μm, and mean axial length was 24.6 ± 3.2 mm. Overall, 89% of MHs closed (78.5% complete; 10% small eccentric defect), with a 95% closure rate in MH-RRD (68.4% complete; 26.3% small eccentric defect). Visual acuity improved by at least 3 lines in 43% of eyes and by at least 5 lines in 29% of eyes. Reconstitution of the EZ (P = 0.02) and ANL (P = 0.01) on OCT were associated with better final VA. Five cases of ART graft dislocation (3.8%), 5 cases of postoperative retinal detachment (3.8%), and 1 case of endophthalmitis (0.77%) occurred.
CONCLUSIONS: In this global experience, patients undergoing ART for large primary and refractory MHs and MH-RRDs achieved good anatomic and functional outcomes, with low complication rates despite complex surgical pathologic features.
Full text links
Related Resources
Trending Papers
Renin-Angiotensin-Aldosterone System: From History to Practice of a Secular Topic.International Journal of Molecular Sciences 2024 April 5
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Revascularization Strategy in Myocardial Infarction with Multivessel Disease.Journal of Clinical Medicine 2024 March 27
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app