Intracranial Air Embolism after Inferior Alveolar Nerve Block: A Case Report.
Clinical Practice and Cases in Emergency Medicine 2020 November
INTRODUCTION: The number of nontraumatic dental pain emergency department (ED) visits continues to substantially rise in frequency every year. While there are several methods for treating dental pain, an inferior alveolar nerve block (IANB) is a non-narcotic alternative that provides instantaneous relief of severe pain.
CASE REPORT: A 59-year-old male presented to the ED from a dentist's office for evaluation of a right-sided headache with an associated episode of palpitations and near syncope that developed while receiving an inferior alveolar nerve block. Computed tomography of the patient's head revealed multiple small foci of air in the right temporalis muscle and in the intracranial venous drainage system. Given the patient's history of dental procedure, the intravascular introduction of air and local anesthetic was suspected.
CONCLUSION: Inferior alveolar nerve block procedures can have complications, including hematoma formation, trismus, facial palsy, needle breakage, and in this case, intravascular injection and cerebral air embolism. To perform a successful IANB, it is critical for providers to be familiar with anatomical landmarks and to consistently perform aspiration to confirm that needle placement is not intravascular.
CASE REPORT: A 59-year-old male presented to the ED from a dentist's office for evaluation of a right-sided headache with an associated episode of palpitations and near syncope that developed while receiving an inferior alveolar nerve block. Computed tomography of the patient's head revealed multiple small foci of air in the right temporalis muscle and in the intracranial venous drainage system. Given the patient's history of dental procedure, the intravascular introduction of air and local anesthetic was suspected.
CONCLUSION: Inferior alveolar nerve block procedures can have complications, including hematoma formation, trismus, facial palsy, needle breakage, and in this case, intravascular injection and cerebral air embolism. To perform a successful IANB, it is critical for providers to be familiar with anatomical landmarks and to consistently perform aspiration to confirm that needle placement is not intravascular.
Full text links
Related Resources
Trending Papers
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app